Fluke 376 FC True-RMS Clamp Meter with iFlex
Flexible iFlex® sensing for accurate professional current measurement
Fluke 376 FC is a professional True RMS clamp meter designed for versatile electrical current measurement, making Fluke 376 FC True-RMS Clamp Meter with iFlex Price in Bangladesh a relevant search term for electricians, engineers, and maintenance technicians. Its iFlex® flexible current probe provides improved access around conductors, while its professional measurement capabilities support electrical troubleshooting, preventive maintenance, and field service applications.
The Fluke 376 FC is designed with True RMS technology to provide reliable measurements when electrical waveforms are variable or distorted. This capability helps professionals evaluate electrical loads more effectively and supports dependable troubleshooting decisions across modern electrical systems.
The iFlex® flexible current probe provides greater access around large conductors and in confined electrical spaces. Its flexible design allows technicians to position the sensing loop where a conventional clamp may be difficult to use, making current measurement more convenient in crowded panels and complex installations.
The Fluke 376 FC supports AC and DC current measurement for a broad range of electrical applications. This versatility makes it suitable for industrial equipment, electrical panels, power systems, motor circuits, maintenance work, and general troubleshooting.
Clamp based measurement allows technicians to measure current without disconnecting conductors or opening the electrical circuit. This non intrusive testing approach can improve efficiency and reduce unnecessary disruption during electrical inspections and maintenance procedures.
The Fluke 376 FC helps technicians investigate current conditions, evaluate electrical loads, and identify abnormal equipment behavior. It can support fault finding, commissioning, preventive maintenance, and service work across commercial and industrial electrical environments.
Electrical panels and machinery often contain limited working space where standard clamp meters can be difficult to position. The iFlex® probe helps overcome these access challenges by providing greater flexibility around conductors and allowing measurements in restricted locations.
The Fluke 376 FC is designed for professional field applications where dependable measurement equipment is essential. Its practical configuration supports routine electrical inspections, maintenance, troubleshooting, equipment servicing, and commissioning activities.
Built for professional electrical environments, the Fluke 376 FC is suitable for repeated handling during field testing and maintenance. Its robust design helps support reliable operation for technicians working in demanding electrical service conditions.
Regular current measurement can help maintenance professionals detect unusual electrical conditions and investigate potential equipment issues. The Fluke 376 FC provides a practical solution for monitoring electrical loads and supporting preventive maintenance programs.
The Fluke 376 FC can be used in industrial facilities, commercial buildings, electrical distribution systems, machinery maintenance, motor applications, and power equipment servicing. Its flexible iFlex® sensing technology adds versatility when working with difficult access conductors.
The Fluke 376 FC combines True RMS technology, AC and DC current measurement, flexible iFlex® sensing, convenient clamp testing, and professional field usability. It is a suitable choice for electricians, electrical engineers, maintenance technicians, and industrial service professionals.
For professionals seeking a versatile clamp meter with flexible current measurement capability, the Fluke 376 FC offers a practical solution. Its iFlex® probe and True RMS technology make it valuable for electrical troubleshooting, maintenance, inspection, and demanding field applications.
| General Specifications | ||||||
| AC Current via Jaw | ||||||
| Range | 999.9 A | |||||
| Resolution | 0.1 A | |||||
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |||||
| 2.5% ±5 digits (100-500 Hz) | ||||||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |||||
| 2.5 @ 600 A | ||||||
| Add 2% for C.F. >2 | ||||||
| AC Current via Flexible Current Probe | ||||||
| Range | 2500 A | |||||
| Resolution | 0.1 A (≤ 600 A) | |||||
| 1 A (≤ 2500 A) | ||||||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |||||
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |||||
| 2.5 at 1400 A | ||||||
| 1.42 at 2500 A | ||||||
| Add 2% for C.F. > 2 | ||||||
![]() |
||||||
| i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | ||||
| A | ||||||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) | |||
| Error | ±0.5 % | ±0.5 % | ±0.5 % | |||
| B | ||||||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) | |||
| Error | ±1.0 % | ±1.0 % | ±1.0 % | |||
| C | ||||||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) | |||
| Error | ±2.0 % | ±2.0 % | ±2.0 % | |||
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||||
| DC Current | ||||||
| Range | 999.9 A | |||||
| Resolution | 0.1 A | |||||
| Accuracy | 2% ±5 digits | |||||
| AC Voltage | ||||||
| Range | 1000 V | |||||
| Resolution | 0.1 V (≤600.0 V) | |||||
| 1 V (≤1000 V) | ||||||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |||||
| DC Voltage | ||||||
| Range | 1000 V | |||||
| Resolution | 0.1 V (≤600.0 V) | |||||
| 1 V (≤1000 V) | ||||||
| Accuracy | 1% ±5 digits | |||||
| mV dc | ||||||
| Range | 500.0 mV | |||||
| Resolution | 0.1 mV | |||||
| Accuracy | 1% ±5 digits | |||||
| Frequency via Jaw | ||||||
| Range | 5.0 Hz to 500.0 Hz | |||||
| Resolution | 0.1 Hz | |||||
| Accuracy | 0.5% ±5 digits | |||||
| Trigger level | 5 Hz to 10 Hz, ≥10 A | |||||
| 10 Hz to 100 Hz, ≥5 A | ||||||
| 100 Hz to 500 Hz, ≥10 A | ||||||
| Frequency via Flexible Current Probe | ||||||
| Range | 5.0 Hz to 500.0 Hz | |||||
| Resolution | 0.1 Hz | |||||
| Accuracy | 0.5% ±5 digits | |||||
| Trigger level | 5 Hz to 20 Hz, ≥25 A | |||||
| 20 Hz to 100 Hz, ≥20 A | ||||||
| 100 Hz to 500 Hz, ≥25 A | ||||||
| Resistance | ||||||
| Range | 60 kΩ | |||||
| Resolution | 0.1 Ω (≤600 Ω) | |||||
| 1 Ω (≤6000 Ω) | ||||||
| 10 Ω (≤60 kΩ) | ||||||
| Accuracy | 1% ±5 digits | |||||
| Capacitance | ||||||
| Range | 1000 μF | |||||
| Resolution | 0.1 μF (≤ 100 μF) | |||||
| 1 μ F (≤ 1000 μF) | ||||||
| Accuracy | 1% ±4 digits | |||||
| Mechanical Specifications | ||||||
| Maximum voltage between any terminal and earth ground | 1000 V | |||||
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |||||
| Operating temperature | -10 °C to +50 °C | |||||
| Storage temperature | -40 °C to +60 °C | |||||
| Operating humidity - non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | |||||
| ≤75% RH (at 30 °C to 40 °C) | ||||||
| ≤45% RH (at 40 °C to 50 °C) | ||||||
| Operating altitude | 2000 m | |||||
| Storage altitude | 12,000 m | |||||
| Size (L x W x H) | 249 x 85 x 45 mm | |||||
| Weight | 395 g | |||||
| Jaw opening | 34 mm | |||||
| Flexible current probe diameter | 7.5 mm | |||||
| Flexible current probe cable length (head to electronics connector) |
1.8 m | |||||
| Safety | IEC 61010-1, Pollution Degree 2 | |||||
| IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||||||
| IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | ||||||
| IP rating | IEC 60529: IP30, non-operating | |||||
| Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE | |||||
| Electromagnetic Compatibility (EMC) | ||||||
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 | |||||
| CISPR 11: Group 1, Class A | ||||||
| Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||||||
| Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | ||||||
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |||||
| Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||||||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |||||
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | |||||
No resources available for this product.