Hioki DT4281 Digital Multimeter
Precision Engineering for Advanced Electrical Testing
Hioki DT4281 is a professional high performance electrical measuring instrument, and the Hioki DT4281 Digital Multimeter Price in Bangladesh is a relevant search term for engineers, electricians, technicians, and maintenance professionals seeking dependable testing equipment. Designed for demanding electrical measurement, troubleshooting, inspection, and maintenance applications, this digital multimeter combines advanced functionality with professional construction and convenient operation.
Reliable and precise measurement is essential when analyzing electrical circuits and equipment. The Hioki DT4281 is designed to deliver dependable measurement performance for professional applications, helping users evaluate electrical conditions, verify system operation, and identify irregularities during testing and diagnostic procedures.
The Hioki DT4281 is designed for professionals who require a versatile measurement instrument for demanding electrical applications. Its advanced functionality makes it suitable for industrial facilities, engineering laboratories, service centers, workshops, and field maintenance environments. It can support both routine inspections and detailed troubleshooting activities.
Professional testing equipment should provide advanced functionality while remaining practical to operate. The Hioki DT4281 is designed with a user focused interface that helps technicians access measurement functions efficiently and interpret results clearly. This can improve workflow during inspection, troubleshooting, and maintenance tasks.
Electrical fault diagnosis requires dependable measurement data. The Hioki DT4281 can assist professionals with circuit inspection, equipment servicing, component testing, and troubleshooting procedures. Its reliable measurement capability helps technicians investigate abnormal electrical conditions and make informed decisions during maintenance and repair work.
Measurement instruments used in demanding environments require robust construction and dependable operation. The Hioki DT4281 is designed for professional applications where durability and long term usability are important. Proper handling, storage, and regular maintenance can help preserve its performance during repeated use.
The Hioki DT4281 is well suited for electrical maintenance and inspection activities in demanding environments. It can support preventive maintenance, equipment servicing, electrical diagnostics, circuit verification, and troubleshooting. Its professional capabilities make it suitable for technicians and engineers working with complex electrical systems.
The Hioki DT4281 Digital Multimeter is suitable for industrial electrical maintenance, engineering laboratories, electrical installation, equipment servicing, electronic troubleshooting, facility inspection, research environments, and professional field service. It is a valuable measurement instrument for users who require dependable performance in demanding electrical applications.
Selecting an advanced digital multimeter requires consideration of measurement precision, functionality, usability, durability, and application requirements. The Hioki DT4281 provides a strong combination of professional measurement capabilities and practical operation, making it suitable for engineers, electricians, technicians, and maintenance professionals who demand dependable testing performance.
A high quality digital multimeter is an essential instrument for accurate electrical testing and troubleshooting. The Hioki DT4281 provides a professional solution for measurement, inspection, diagnostics, and maintenance applications. Its advanced functionality, durable construction, and convenient operation make it a reliable choice for demanding electrical and engineering environments.
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to a DMM's many ranges and functions, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | |||||
|---|---|---|---|---|---|---|
| AC Voltage* range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|||||
| DC + AC Voltage* range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|||||
| Resistance range | 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt. | |||||
| DC Current range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.05 % rdg. ±5 dgt. |
|||||
| AC Current* range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
|||||
| AC Current* range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges Add the Clamp on probe accuracy to Basic accuracy 40 - 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3) |
|||||
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|||||
| Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. | |||||
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more | |||||
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages | |||||
| Frequency range | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
|||||
| dB conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV) |
|||||
| Temperature (thermocouples) | K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C |
|||||
| Other functions | Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion | |||||
| Display | Main and sub displays: 5-digits LCD, max. 60000 digits | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) | |||||
| Power supply | LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours | |||||
| Dimensions and mass | 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) | |||||
| Included accessories | Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4 | |||||
N/A
No resources available for this product.
No reviews yet. Be the first to review this product!