Extech HD350 Pitot Tube Anemometer Plus Differential Manometer
Reliable Airflow and Differential Pressure Testing for Professional Applications
The Extech HD350 Pitot Tube Anemometer Plus Differential Manometer is a practical instrument for technicians who need to evaluate airflow and pressure conditions in ventilation systems and industrial environments, making the Extech HD350 Pitot Tube Anemometer Plus Differential Manometer Price in Bangladesh a relevant search for HVAC professionals, maintenance engineers, and industrial buyers. By combining airflow measurement with differential pressure testing, this instrument supports a range of inspection and troubleshooting tasks where reliable measurement data is essential.
Pitot tube technology determines airflow velocity by measuring pressure differences associated with moving air. This method is particularly useful when assessing airflow inside ducts, ventilation channels, and air distribution systems. The HD350 is designed to work with a compatible Pitot tube, allowing technicians to investigate air movement in locations where direct airflow measurement may be difficult.
The resulting measurements can help professionals assess ventilation performance, investigate uneven air distribution, and identify conditions that may require adjustment or maintenance. Correct probe positioning and suitable measurement procedures remain important for obtaining meaningful results.
Differential pressure measurement helps engineers understand the pressure difference between two points in a system. The Extech HD350 supports this type of assessment, making it useful for checking pressure conditions in HVAC installations, ductwork, filters, and other compatible applications.
Technicians can use differential pressure readings to investigate restricted airflow, identify possible blockages, and evaluate system operating conditions. When measurements are taken consistently, the results can help maintenance teams compare system performance over time and make better-informed service decisions.
Heating, ventilation, and air conditioning systems require proper airflow to maintain comfortable indoor conditions and support efficient operation. The HD350 can assist during ventilation inspections, system commissioning, and routine maintenance by providing measurement data relevant to airflow and pressure evaluation.
Building maintenance teams may use the instrument when examining supply and return air ducts, investigating ventilation complaints, or checking whether air distribution requires further adjustment. It can also support troubleshooting when filters, dampers, fans, or duct sections may be affecting system performance.
Industrial facilities often depend on controlled air movement for production processes, equipment cooling, extraction systems, and workplace ventilation. The Extech HD350 provides measurement capabilities that can support inspection activities in suitable industrial environments.
Maintenance engineers can use airflow and pressure information to investigate ventilation performance and help identify developing operational issues. The instrument may also be useful for contractors and service professionals working with air handling equipment, subject to the measurement requirements and operating conditions of each application.
For field measurements, an instrument must be straightforward to use and suitable for the testing procedure. The HD350 is intended for airflow and differential pressure assessment, helping technicians gather information during inspections without relying solely on visual observations or estimates.
Before taking measurements, users should select the correct mode, confirm the required connections, inspect the Pitot tube and tubing, and follow the manufacturer's operating instructions. Stable positioning and appropriate measurement points help improve consistency, particularly when comparing readings from different locations within a ventilation system.
Reliable measurement data can make maintenance work more systematic. Rather than assuming that an airflow problem comes from a fan or blocked duct, technicians can use pressure and velocity readings to investigate the system more methodically.
Recording measurement results alongside inspection notes can also help maintenance teams track changes after cleaning, repairs, filter replacement, or ventilation adjustments. This approach supports more informed troubleshooting and can reduce unnecessary component replacement when the underlying cause has not yet been identified.
Proper handling helps preserve instrument performance. The meter, pressure connections, tubing, and Pitot tube should be inspected regularly for visible damage, contamination, loose connections, or obstructions. Keeping the sensing components clean and storing the instrument according to the manufacturer's recommendations can help maintain dependable operation.
For measurement-critical work, users should also follow the recommended calibration schedule and verify that the instrument's measurement range and accuracy are suitable for the intended task. Environmental conditions, probe placement, and airflow characteristics can influence readings and should be considered during testing.
Before purchasing the Extech HD350, consider the types of airflow and pressure measurements required at your workplace. Confirm that its measurement functions, operating ranges, accuracy, included accessories, and compatibility with the intended Pitot tube meet your application needs.
Buyers should also verify whether the supplied package includes the accessories required for immediate testing. Depending on the supplier, additional probes, tubing, carrying cases, or other accessories may need to be purchased separately. Reviewing the official product documentation helps avoid compatibility issues and ensures that the instrument is suitable for the planned inspection tasks.
Professionals searching for the Extech HD350 Pitot Tube Anemometer Plus Differential Manometer in Bangladesh should compare supplier information, product authenticity, warranty coverage, and after-sales support before ordering. Local availability may vary, so buyers should confirm current stock and the exact contents of the package with the supplier.
For industrial companies, HVAC contractors, laboratories, and maintenance departments, selecting an instrument from a dependable supplier helps simplify procurement and technical support. Product documentation and service assistance are particularly valuable when the instrument will be used for routine inspections or measurement-based maintenance programs.
The Extech HD350 brings together airflow velocity assessment using Pitot tube technology and differential pressure measurement in a single instrument. Its intended applications include HVAC inspection, ventilation troubleshooting, industrial maintenance, and other compatible air measurement tasks.
For engineers and technicians seeking an airflow and differential pressure testing solution, the model is worth evaluating against the specific demands of their work. Checking the offi
| Range | Resolution | Accuracy | |
| Pressure | |||
| psi | 0.7252psi | 0.0001psi | ±0.3%FS |
| mbar | 50.00mbar | 0.01mbar | ±0.3%FS |
| inH2O | 20.07inH2O | 0.01inH2O ±0 | ±0.3%FS |
| mmH2O | 509.8mmH2O | 0.01mmH2O | ±0.3%FS |
| Pa | 5000Pa | 1Pa | ±0.3%FS |
| Repeatability | ±0.2% (Max. ±0.5%FS) | ||
| Linearity/Hysteresis | ±0.29FS | ||
| Maximum Pressure | 10psi | ||
| Response Time | 0.5s typical | ||
| Air Velocity | |||
| ft/min | 200 to 15733 | 1 | ±3% rdg |
| m/s | 1 to 80.00 | 0.01 | ±3% rdg |
| km/h | 3.5 to 288.0 | 0.1 | ±3% rdg |
| MPH | 2.25 to 178.66 | 0.01 | ±3% rdg |
| knots | 2.0 to 154.6 | 0.1 | ±3% rdg |
| Air Flow | |||
| CFM | 0 to 99,999 | 0.001 | ±3% rdg |
| CMM | 0 to 99,999 | 0.001 | ±3% rdg |
| Temperature | |||
| °F | 32.0 to 122.0°F | 0.1° | ±2°F |
| °C | 0 to 50°C | 0.1° | ±1°C |
| Dimensions/Weight | |||
| Meter | 8.2 x 2.9 x 1.9" (210 x 75 x 50mm) / 12oz (340g) | ||
| Pitot Tube | 15.4 x 7.7” (390 x 195mm) / 7.2oz (204g) | ||
Test Equipment General Attributes |
|
|---|---|
| Unique Features | Simultaneous display of Pressure, Air Velocity or Air Flow plus Temperature ±0.7252psi range 5 selectable units of pressure measurement Max/Min/Avg recording and Relative time stamp Data Hold and Auto power off functions Large LCD display with backlighting Zero function for offset correction or measurement Store/Recall up to 99 readings in each mode USB port includes software |
| Warranty | 3 YEARS |
| Safety Approval | CE |
| Product Weight | 340 GRAMS (0.750 LBS) |
| Product Height | 2.9 IN |
| Product Length | 1.9 IN |
| Product Width | 8.2 IN |
| Data Logging | No |
| HTS/Schedule B Number | 9026.80.4000 |
| ECCN Number | EAR99 |
| Calibration Included | Factory Calibration |
| Power Supply Voltage | 120V/220V Universal |
| Country of Origin | China |
N/A
No resources available for this product.
No reviews yet. Be the first to review this product!