Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
Powerful Industrial Troubleshooting in a Rugged Handheld ScopeMeter
The Fluke 120B Series combines the portability of a handheld test instrument with the diagnostic capabilities required for industrial electrical maintenance, making it a practical choice for engineers and technicians searching for Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes Price in Bangladesh. Designed for troubleshooting electrical and electromechanical systems, the ScopeMeter platform helps users observe signals, identify abnormal operating conditions, and diagnose equipment faults directly at the installation site.
The Fluke 120B Series is engineered for fast and dependable troubleshooting in industrial environments. Its integrated oscilloscope, multimeter, and recorder functions allow technicians to investigate electrical problems without carrying multiple instruments. This integrated approach can simplify field testing and help reduce the time required to identify intermittent or complex faults.
A compact handheld construction makes the ScopeMeter suitable for maintenance work where bench instruments are impractical. The portable design allows engineers to move between control panels, machinery, electrical cabinets, and field installations while maintaining access to essential measurement and waveform analysis functions.
The instrument provides clear visualization of electrical waveforms, helping users evaluate signal behavior and recognize irregularities that may not be apparent from conventional multimeter measurements. Waveform analysis can be particularly useful when investigating switching problems, unstable signals, motor control issues, power quality disturbances, and electronic control circuits.
The Fluke 120B Series integrates multiple measurement capabilities into a single troubleshooting platform. Engineers can use its measurement functions to examine voltage, current, resistance, continuity, and other electrical parameters while combining numerical readings with waveform information for a more complete understanding of system behavior.
Designed with industrial service requirements in mind, the ScopeMeter incorporates features that support efficient fault finding. Automated measurement capabilities, waveform capture, trend analysis, and signal comparison can help technicians identify changes in equipment performance and investigate problems that occur intermittently.
Electrical troubleshooting often requires measurements around demanding industrial installations. The Fluke 120B Series is designed with safety and practical field use in mind, making it suitable for qualified professionals working on electrical distribution systems, automation equipment, motor drives, control circuits, and industrial machinery.
Durability is an important consideration for equipment used in industrial maintenance. The handheld ScopeMeter design is built to withstand the demands of field service environments, allowing engineers to use the instrument across maintenance workshops, production facilities, electrical installations, and other challenging locations.
The Fluke 120B Series can support a wide range of professional applications, including industrial automation troubleshooting, motor and drive diagnostics, control system analysis, electrical maintenance, power system investigation, machinery servicing, and preventive maintenance. Its multifunctional design makes it useful for both routine inspections and detailed fault diagnosis.
Choosing the Fluke 120B Series can provide engineers with a versatile troubleshooting solution that combines portability, measurement capability, waveform analysis, and dependable industrial performance. Its integrated functionality helps reduce the need for separate instruments and enables technicians to approach electrical problems from both measurement and signal analysis perspectives.
For engineers, maintenance professionals, electrical technicians, and industrial service teams in Bangladesh, the Fluke 120B Series offers a practical solution for field based electrical troubleshooting. Its combination of handheld convenience, professional measurement functions, waveform analysis, and rugged construction makes it well suited to demanding industrial maintenance applications.
| Oscilloscope mode | ||
| Vertical | ||
| Frequency response - dc coupled | Without probes and test leads (with BB120) | 123B: dc to 20 MHz (-3 dB) 124B and 125B: dc to 40 MHz (-3 dB) |
| With STL120-IV 1:1 shielded test leads | DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB) | |
| With VP41 10:1 Probe | 123B: dc to 20MHz (-3 dB) 124B and 125B: dc to 40 MHz (-3 dB) |
|
| Frequency response - ac coupled (lf roll off) | Without probes and test leads | <10 Hz (-3 dB) |
| With STL120-IV 1:1 shielded test leads | <10 Hz (-3 dB) | |
| With VP41 10:1 Probe | <10 Hz (-3 dB) | |
| Rise time, excluding probes, test leads |
123B <17.5 ns 124B and 125B <8.75 ns |
|
| Input impedance | Without probes and test leads | 1 MΩ//20 pF |
| With BB120 | 1 MΩ//24 pF | |
| With STL120-IV 1:1 shielded test leads | 1 MΩ//230 pF | |
| With VP41 10:1 Probe | 5 MΩ//15.5 pF | |
| Sensitivity | 5 mV to 200 V/div | |
| Analog bandwidth limiter | 10 kHz | |
| Display modes | A, -A, B, -B | |
| Max. input voltage A and B | Direct, with test leads, or with VP41 Probe | 600 Vrms Cat IV, 750 Vrms maximum voltage. |
| With BB120 | 600 Vrms | |
| Max. floating voltage, from any terminal to ground | 600 Vrms Cat IV, 750 Vrms up to 400Hz | |
| Horizontal | ||
| Scope modes | Normal, Single, Roll | |
| Ranges (normal) | Equivalent sampling | 123B: 20 ns to 500 ns/div, |
| 124B and 125B: 10 ns to 500 ns/div | ||
| Real time sampling | 1 μs to 5 s/div | |
| Single (real time) | 1 μs to 5 s/div | |
| Roll (real time) | 1s to 60 s/div | |
| Sampling rate (for both channels simultaneously) | Equivalent sampling (repetitive signals) | Up to 4 GS/s |
| Real time sampling 1 μs to 60 s/div | 40 MS/s | |
| Trigger | ||
| Screen update | Free run, on trigger | |
| Source | A, B | |
| Sensitivity A and B | @ DC to 5 MHz | 0.5 divisions or 5 mV |
| @ 40 MHz | 123B: 4 divisions | |
| 124B and 125B: 1.5 divisions | ||
| @ 60 MHz | 123B: N/A | |
| 124B and 125B: 4 divisions | ||
| Slope | Positive, negative | |
| Advanced scope functions | ||
| Display modes | Normal | Captures up to 25 ns glitches and displays analog-like persistence waveform |
| Smooth | Suppresses noise from a waveform | |
| Glitch off | Does not capture glitches between samples | |
| Envelope | Records and displays the minimum and maximum of waveforms over time | |
| Auto set (Connect-and-View™) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level. | |
| Dual input meter | ||
| The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C. | ||
| Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen. |
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| 10,000 counts | ||
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range - 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
| Input A to common | ||
| Ohm (Ω) | ||
| Ranges | 123B and 124B | 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ |
| 125B | 50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | |
| Accuracy | ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts) | |
| Full scale reading | 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts | |
| Measurement current | 0.5 mA to 50 nA, decreases with increasing ranges | |
| Open circuit voltage | <4 V | |
| Continuity (Cont) | ||
| Beep | <(30 Ω ±5 Ω) in 50 Ω range | |
| Measurement current | 0.5 mA | |
| Detection of shorts of | ≥1 ms | |
| Diode | ||
| Measurement voltage | @0.5 mA | >2.8 V |
| @open circuit | <4 V | |
| Measurement current | 0.5 mA | |
| Polarity | + on input A, - on COM | |
| Capacitance (CAP) | ||
| Ranges | 50 nF, 500 nF, 5 μF, 50 μF, 500 μF | |
| Full scale reading | 5000 counts | |
| Measurement current | 500 nA to 0.5 mA, increases with increasing ranges | |
| Advanced meter functions | ||
| Zero Set | Set actual value to reference | |
| AutoHold (on A) | Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. | |
| Fixed decimal point | Activated by using attenuation keys | |
| Cursor Readout (124B and 125B) | ||
| Sources | A, B | |
| Single vertical line | Average, min and max readout | |
| Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD) | ||
| Min, max and time from start of readout (in RECORDER mode; instrument in HOLD) | ||
| Harmonics values in POWER QUALITY mode. | ||
| Dual vertical lines | Peak-peak, time distance and reciprocal time distance readout | |
| Average, min, max and time distance readout (in ROLL mode; instrument in HOLD) | ||
| Dual horizontal lines | High, low and peak-peak readout | |
| Rise or fall time | Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode) |
|
| Accuracy | As oscilloscope accuracy | |
| Recorder | ||
| The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B). | ||
| The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples. | ||
| Meter readings | ||
| Measurement Speed | Maximum 2 measurement/s | |
| Recor | ||