Fluke 1586A Super-DAQ Precision Temperature Scanner

Precision temperature scanning for advanced measurement and testing

  • Home
  • Products
  • Fluke 1586A Super-DAQ Precision Temperature Scanner
Fluke 1586A Super-DAQ Precision Temperature Scanner
Brand: Fluke
Category: Temperature Calibrators
Availability: Ready Stock
Always authentic product We only sell 100% authentic products
Fast Shipping Receive products in amazing time.
Easy returns Return policy that let you shop at ease
Secure shopping Your data is always protected

Fluke 1586A Super-DAQ Precision Temperature Scanner Price in Bangladesh

Fluke 1586A Super DAQ Precision Temperature Scanner is a professional data acquisition and temperature measurement solution, making Fluke 1586A Super DAQ Precision Temperature Scanner Price in Bangladesh a relevant search for engineers, calibration specialists, laboratory technicians, and industrial professionals. Designed for demanding temperature measurement and monitoring applications, this precision scanner helps users collect, analyze, and document temperature data efficiently. Its professional architecture makes it suitable for laboratory testing, calibration, research, manufacturing, and quality assurance environments.

Precision Temperature Scanning

The Fluke 1586A is designed to provide dependable temperature scanning across compatible measurement channels and sensors. This makes it useful for applications where multiple temperature points need to be monitored and evaluated systematically. Engineers can use the instrument to identify temperature variations, investigate thermal behavior, and support measurement verification procedures without relying on separate instruments for every measurement point.

Advanced Data Acquisition

Effective temperature testing requires more than simply displaying a measurement. The Fluke 1586A combines temperature scanning with data acquisition capabilities to help professionals capture and evaluate measurement information. Recorded data can support troubleshooting, quality control, process analysis, calibration activities, and technical reporting. This makes the instrument particularly useful where historical temperature information is important for engineering decisions.

Laboratory and Calibration Applications

The Super DAQ Precision Temperature Scanner is well suited to calibration laboratories and technical testing environments. It can support temperature sensor verification, equipment testing, thermal characterization, and measurement system evaluation. Its precision focused design provides professionals with a practical platform for collecting temperature data during controlled laboratory procedures.

Industrial Temperature Monitoring

Industrial processes often require temperature monitoring at multiple locations to maintain consistent operating conditions. The Fluke 1586A can assist engineers and technicians with monitoring temperature across compatible sensors and measurement points. It can be incorporated into equipment testing, preventive maintenance, process evaluation, and quality assurance workflows where reliable temperature information is essential.

Flexible Measurement Capability

A major benefit of a professional temperature scanner is its ability to support different measurement requirements within one system. The Fluke 1586A is designed to work with compatible temperature sensors and measurement configurations, allowing users to build a testing setup appropriate for their application. Proper sensor selection and configuration are important for achieving the desired measurement performance.

Professional Data Management

Organized measurement data is valuable for engineering analysis and documentation. The Fluke 1586A provides a professional platform for acquiring temperature information and supporting systematic evaluation. Recorded measurements can help technicians compare test conditions, identify abnormal thermal behavior, and maintain useful records for quality control and maintenance programs.

Reliable Engineering Design

Professional data acquisition equipment must be dependable during repeated laboratory and industrial use. The Fluke 1586A is engineered for technical measurement applications where consistent operation is important. Proper installation, suitable operating conditions, regular verification, and appropriate maintenance can help preserve the instrument's performance and extend its service life.

Suitable for Engineers and Technicians

The Fluke 1586A Super DAQ Precision Temperature Scanner is suitable for calibration engineers, laboratory professionals, research teams, manufacturing specialists, maintenance technicians, and quality assurance personnel. Its combination of temperature scanning and data acquisition makes it valuable for users who need structured temperature measurement rather than isolated readings.

Applications in Bangladesh

The Fluke 1586A can support temperature measurement and data acquisition requirements across laboratories, manufacturing facilities, pharmaceutical operations, research institutions, industrial plants, and calibration service providers in Bangladesh. It can assist with sensor testing, equipment validation, thermal studies, preventive maintenance, and quality control. Before deployment, users should verify sensor compatibility and ensure the measurement configuration matches their specific application requirements.

Why Choose Fluke 1586A

The Fluke 1586A Super DAQ Precision Temperature Scanner combines precision temperature measurement, multi point scanning, and professional data acquisition in a dedicated testing platform. Its versatility makes it suitable for demanding laboratory and industrial applications where dependable temperature information is essential. With appropriate sensors and proper measurement practices, it can support efficient testing, analysis, calibration, and long term temperature monitoring.

Key Features: Fluke 1586A Super-DAQ Precision Temperature Scanner

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
  • Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
  • Scan up to 10 channels per second, great for high-speed applications.
  • Four operation modes - Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
  • Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.

Specifications: Fluke 1586A Super-DAQ Precision Temperature Scanner

General Specifications
Mains Voltage 100 V Setting: 90 V to 110 V
120 V Setting: 108 V to 132 V
220 V Setting: 198 V to 242 V
240 V Setting: 216 V to 264 V
Frequency 47 Hz to 440 Hz
Power Consumption  36 VA peak (24 W average)
Environment Temperature Operating: 0 °C to 50 °C
Full accuracy: 18 °C to 28 °C
Storage: −20 °C to 70 °C
Warm-up: 1 hour to full accuracy specifications
Relative Humidity (non-condensing) Operating:  0 °C to 30 °C <80 %;
                   30 °C to 50 °C <50 %
Storage: −20 °C to 70 °C <95 %
Altitude Operating: 2,000 m
Storage: 12,000 m
Vibration and Shock  Complies with MIL-PRF-28800F Class 3
Channel Capacity Total analog channels: 45
Voltage/resistance channels: 41
Current channels:  5
Digital I/O: 8 bits
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Channel Input Connector Types 1586A Channel 001 (front panel): gold pins, bare wire, spade lugs, banana plugs
DAQ-STAQ Multiplexer: gold pins, bare wire, mini spade lugs, mini banana plugs, mini-jack thermocouple
High-Capacity Module: gold pins, bare wire
Input Protection  50 V all functions, terminals and ranges
Math Channels Number of channels: 20
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
Memory Scan data RAM: 75,000 readings with timestamp
Data/Setup flash memory: 20 MB
USB Host Port Connector type: Type A
Function: Memory
File system: FAT32
Memory capacity: 32 GB
USB Device Port Connector type: Type B
Class: Instrument
Function: Control and data transfer
Command protocol: SCPI
LAN Function: Control and data transfer
Network protocols: Ethernet 10/100, TCP/IP
Command protocol: SCPI
RS-232 Connector: D-sub 9 pin (DE-9)
Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
Function: Temperature source control output
Dimensions Height: 150 mm
Width: 245 mm
Depth: 385 mm Weight: 6 kg (typical configuration)
Shipping Weight: 9.5 kg (typical configuration)
Conformity CE, CSA, IEC 61010 3rd ed.
Measurement Specifications
Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted), after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of calibration.
Scan rate Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel)
Slow: 4 seconds per channel
Display Resolution 6 1/2 digits (see Measurement Characteristics tables below to find the display resolution of temperature readings)
PRT/RTD
Temperature Range −200 °C to 1200 °C (depending on the sensor)
Resistance Range 0 Ω to 4 kΩ
Offset Compensation 0 Ω to 400 Ω, 4-wire: automatic current reversal
400 Ω to 4000 Ω or 3-wire: none
Source Current Reversal Interval (0 Ω  to 400 Ω range)  Fast sample rate: 2 ms
Medium sample rate: 250 ms
Slow sample rate: 250 ms
Maximum Lead Resistance (4-wire Ω)  2.5 % of range per lead for 400 Ω and 4 kΩ ranges
PRT/RTD Resistance Accuracy
Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Sample Rate DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
0 Ω to 400 Ω Slow 0.002 % or 0.0008 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
Medium 0.002 % or 0.002 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
Fast 0.002 % or 0.005 Ω 0.003 % or 0.006 Ω 0.0001 % or 0.0008 Ω
400 Ω to 4 kΩ Slow 0.004 % or 0.06 Ω 0.006 % or 0.06 Ω 0.0001 % or 0.008 Ω
Medium 0.004 % or 0.1 Ω 0.006 % or 0.1 Ω 0.0001 % or 0.008 Ω
Fast 0.004 % or 0.18 Ω 0.006 % or 0.18 Ω 0.0001 % or 0.008 Ω
PRT/RTD Temperature Accuracy
Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temper
ature coefficient n umber by the temperature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor and characterization.
Sample Rate Temperature DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
Slow −200 °C 0.002 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Medium −200 °C 0.005 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Fast −200 °C 0.013 °C 0.015 °C 0.002 °C
0 °C 0.013 °C 0.015 °C 0.003 °C
300 °C 0.014 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
PRT/RTD Measurement Characteristics
  Temperature Display Resolution  
Range Slow / Medium Sample Rate Fast Sample Rate Source Current
0 Ω to 400 Ω 0.001 °C 0.01 °C ±1 mA
400 Ω to 4 kΩ 0.001 °C 0.01 °C 0.1 mA
Thermistor
Temperature Range  −200 °C to 400 °C (depending on the sensor)
Resistance Range  0 Ω to 1 MΩ
Thermistor Resistance Accuracy
Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor, slow sample rate. When using medium or fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For 2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or
1.5 Ω if using channels x01 through x20, and add external lead wire resistance.
Range Slow Sample Rate Medium Sample Rate Rate Fast Sample Rate T.C./ °C Outside18 °C to 28 °C
0 Ω to 2.2 kΩ 0.004 % + 0.2 Ω add 0.3 Ω add 1 Ω 0.0005 % + 0.05 Ω
2.1 kΩ to 98 kΩ 0.004 % + 0.5 Ω add 0.5 Ω add 1.3 Ω 0.0005 % + 0.1 Ω
95 kΩ to 1 MΩ 0.015 % + 5 Ω add 5 Ω add 13 Ω 0.001 % + 2 Ω
Thermistor Temperature Accuracy
Accuracy specifications are for 4-wire thermistor. When using 2-wire thermistor, add the number given in the table to the specification for internal resistance. If the environment temperature is outside the specified range, increase the accuracy specification by 25 % for every 1 °C outside the specified environment temperature range. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
Accuracy 2.2 kΩ Thermistor
Temperature SlowSample Rate MediumSample Rate FastSample Rate 2-wire
−40 °C 0.001 °C 0.001 °C 0.01 °C add 0.001 °C
0 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
25 °C 0.006 °C 0.011 °C 0.02 °C add 0.016 °C
50 °C 0.008 °C 0.018 °C 0.04 °C add 0.05 °C
100 °C 0.047 °C 0.114 °C 0.28 °C add 0.34 °C
150 °C 0.23 °C 0.56 °C 1.34 °C add 1.7 °C
Accuracy 5 kΩ Thermistor
Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.004 °C 0.006 °C 0.01 °C add 0.007 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.022 °C
100 °C 0.022 °C 0.052 °C 0.13 °C add 0.16 °C
150 °C 0.096 °C 0.24 °C 0.57 °C add 0.7 °C
Accuracy 10 kΩ Thermistor
Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.011 °C
100 °C 0.011 °C 0.024 °C 0.06 °C add 0.067 °C
150 °C 0.04 °C 0.098 °C 0.24 °C add 0.29 °C
Thermistor Measurement Characteristics
  Temperature Display Resolution  
Range Slow / Medium
Sample Rate
Fast
Sample Rate
Source Current
0 Ω to 2.2 Ω 0.0001 °C 0.001 °C 10 μA
2.1 Ω to 98 Ω 0.0001 °C 0.001 °C 10 μA
95 Ω  to 1 MΩ 0.0001 °C 0.001 °C 1 μA
Thermocouple
Temperature Range −270 °C to 2315 °C (depending on the sensor)
Voltage Range −15 mV to 100 mV
Thermocouple Voltage Accuracy
Accuracy is given as ± (|% of measurement| + μV). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
−15 mV to 100 mV 0.004 % + 4 μV add 2 μV add 1 μV 0.0005 % + 0.0005 mV
Thermocouple Reference Junction Accuracy
Module CJC Accuracy T.C./ °C Outside
18 °C to 28 °C
DAQ-STAQ Module 0.25 °C 0.02 °C
High-Capacity Module 0.6 °C 0.05 °C
Thermocouple Temperature Accuracy
Accuracy specifications apply using medium or slow sample rate. When using fast sample rate, increase the accuracy specification by 25 %. If the environment temperature is outside the specified range, increase the accuracy specification by 12 % for every 1 °C outside the specified environment temperature range. Accuracy with fixed/external CJC does not include the accuracy of the reference junction temperature. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
Type
(Range)
Temperature Accuracy
Fixed / External CJC Internal CJC
Channel 1 Ch. x01 – x20 DAQ-STAQ Module High-Capacity
Module
K
−270 °C to
1372 °C
−200 °C
0 °C
1000 °C
0.28 °C
0.10 °C
0.14 °C
0.41 °C
0.15 °C
0.20 °C
0.76 °C
0.29 °C
0.32 °C
1.60 °C
0.62 °C
0.64 °C
T
−270 °C to
400 °C
−200 °C
0 °C
200 °C
400 °C
0.27 °C
0.10 °C
0.08 °C
0.08 °C
0.40 °C
0.15 °C
0.12 °C
0.11 °C
0.76 °C
0.30 °C
0.23 °C
0.20 °C
1.60 °C
0.65 °C
0.47 °C
0.41 °C
R
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.76 °C
0.42 °C
0.33 °C
0.34 °C
1.13 °C
0.63 °C
0.47 °C
0.49 °C
1.16 °C
0.64 °C
0.48 °C
0.50 °C
1.28 °C
0.71 °C
0.52 °C
0.54 °C
S
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.74 °C
0.45 °C
0.37 °C
0.39 °C
1.11 °C
0.67 °C
0.54 °C
0.56 °C
1.14 °C
0.68 °C
0.55 °C
0.57 °C
1.26 °C
0.76 °C
0.60 °C
0.63 °C
J
−210 °C to
1200 °C
−200 °C
0 °C
1000 °C
0.20 °C
0.08 °C
0.11 °C
0.29 °C
0.12 °C
0.14 °C
0.65 °C
0.28 °C
0.25 °C
1.41 °C
0.61 °C
0.53 °C
N
−270 °C to
1300 °C
−200&
nbsp;°C
0 °C
500 °C
1000 °C
0.42 °C
0.15 °C
0.12 °C
0.14 °C
0.62 °C
0.23 °C
0.17 °C
0.19 °C
0.90 °C
0.34 °C
0.24 °C
0.26 °C
1.69 °C
0.64 °C
0.44 °C
0.45 °C
E
−270 °C to
1000 °C
−200 °C
0 °C
300 °C
700 °C
0.17 °C
0.07 °C
0.06 °C
0.08 °C
0.25 °C
0.10 °C
0.09 °C
0.10 °C
0.64 °C
0.27 °C
0.21 °C
0.21 °C
1.42 °C
0.61 °C
0.46 °C
0.45 °C
B
100 °C to
1820 °C
300 °C
600 °C
1200 °C
1600 °C
1.32 °C
0.68 °C
0.41 °C
0.38 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
C
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.23 °C
0.28 °C
0.44 °C
0.33 °C
0.40 °C
0.60 °C
0.37 °C
0.45 °C
0.66 °C
0.54 °C
0.63 °C
0.91 °C
D
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.22 °C
0.26 °C
0.39 °C
0.32 °C
0.36 °C
0.53 °C
0.34 °C
0.39 °C
0.56 °C
0.44 °C
0.49 °C
0.69 °C
G
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C
L
−200 °C to
900 °C
−200 °C
0 °C
800 °C
0.13 °C
0.08 °C
0.09 °C
0.19 °C
0.12 °C
0.12 °C
0.45 °C
0.28 °C
0.23 °C
0.99 °C
0.62 °C
0.48 °C
M
−50 °C to
1410 °C
0 °C
500 °C
1000 °C
0.11 °C
0.10 °C
0.10 °C
0.16 °C
0.15 °C
0.14 °C
0.30 °C
0.25 °C
0.21 °C
0.64 °C
0.51 °C
0.41 °C
U
−200 °C to
600 °C
−200 °C
0 °C
400 °C
0.25 °C
0.10 °C
0.08 °C
0.37 °C
0.15 °C
0.11 °C
0.71 °C
0.30 °C
0.20 °C
1.48 °C
0.63 °C
0.40 °C
W
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C
Thermocouple Measurement Characteristics
Range Temperature Display Resolution
Slow / Medium
Sample Rate
Fast
Sample Rate
−270 °C to 2315 °C 0.01 °C 0.1 °C
DC Voltage
Maximum Input 50 V on any range
Common Mode Rejection 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak maximum
Normal Mode Rejection 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum
A/D Linearity 2 ppm of measurement + 1 ppm of range
Input Bias Current 30 pA at 25 °C
DC Voltage Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
±100 mV 0.0037 % + 0.0035 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0005 %
±1 V 0.0025 % + 0.0007 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0001 %
±10 V 0.0024 % + 0.0005 % − add 0.0008 % of range 0.0005 % + 0.0001 %
±50 V 0.0038 % + 0.0012&nb
sp;%
− add 0.0008 % o f range 0.0005 % + 0.0001 %
DC Voltage Input Characteristics
  Resolution Input Impedance
Range Slow / Medium Fast
±100 mV 0.1 μ 1 μ 10 GΩ [1]
±1 V 1 μ 10 μ 10 GΩ [1]
±10 V 10 μ 100 μ 10 GΩ [1]
±50 V 100 μ 1 mV 10 MΩ ±1 %
[1] - Input beyond ±12 V is clamped. The clamp current is up to 3 mA.
DC Current
Input Protection  0.15 A resettable PTC
DC Current Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
±100 μA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±1 mA 0.015 % + 0.0011 % add 0.0008 % of range 0.002 % + 0.001 %
±10 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±100 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
DC Current Input Characteristics
  Resolution  
Range Slow / Medium Fast Burden Voltage
±100 μA 0.1 nA 1 nA <1 mV
±1 mA 1 nA 10 nA <1 mV
±10 mA 10 nA 100 nA <1 mV
±100 mA 100 nA 1 μA <1 mV
Resistance
Max. Lead Resistance (4-wire ohms)  10 Ω per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges.
Resistance Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for 4-wire resistance, medium or slow sample rate. For 2-wire resistance add 0.02 Ω internal resistance if using Channel 1, or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. When using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the Temperature Coefficient numbers by the temperature deviation and add to the accuracy specification
Range Accuracy Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
100 Ω 0.004 % + 0.0035 % add 0.001 % of range[1] 0.0001 % + 0.0005 %
1 kΩ 0.003 % + 0.001 % add 0.001 % of range[2] 0.0001 % + 0.0001 %
10 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
100 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
1 MΩ 0.004 % + 0.001 % add 0.006 % of reading plus 0.0008 % of range 0.0005 % + 0.0002 %
10 MΩ 0.015 % + 0.001 % add 0.2 % of reading plus 0.0008 % of range 0.001 % + 0.0004 %
100 MΩ 0.8 % + 0.01 % add 0.01 % of range 0.05 % + 0.002 %
Notes:
For conducted disturbances on mains input >1 V from 10 MHz to 40 MHz, add 0.6 % of range. For disturbances >3 V, accuracy is unspecified.

[1] 0.15 % of range for 2-wire
[2] 0.015 % of range for 2-wire
Resistance Input Characteristics
Range Resolution
Slow / Medium
Fast Source Current
(open-circuit voltage)
100 Ω 0.1 mΩ 1 mΩ 1 mA (4 V)
1 kΩ 1 mΩ 10 mΩ 1 mA (4 V)
10 kΩ 10 mΩ 100 mΩ 100 μA (6 V)
100 kΩ 100 mΩ 1 Ω 100 μA (12 V)
1 MΩ 1 Ω 10 Ω 10 μA (12 V)
10 MΩ 10 Ω 100 Ω 1 μA (12 V)
100 MΩ 100 Ω 1 kΩ 0.1 μA (12 V)
Digital I/O
Absolute Voltage Range   –4 V to 30 V
Input Minimum Logic High 2.0 V
Input Maximum Logic Low  0.7 V
Output Type  open drain active low
Output Logic Low (<1 mA)  0 V to 0.7 V
Maximum Sink Current  50 mA
Output Resistance  47 Ω
Totalizer
Absolute Voltage Range  –4 V to 30 V
Minimum Logic High  2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Frequency  10 kHz
Debounce Time 1.7 ms
Maximum Count 1048575 (20 bits)
colspan="2">Trigger
Absolute Voltage Range  –4 V to 30 V
Minimum Logic High  2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Latency 100 ms
Alarm Output
Absolute Voltage Range  –4 V to 30 V
Output Type  open drain active low
Output Logic Low (<1 mA) 0 V to 0.7 V
Maximum Sink Current  50 mA
Output Resistance  47 Ω
1586-2588 DAQ-STAQ Input Module Specifications
Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch  <50 mΩ
Basic CJC Accuracy  0.25 °C
1586-2586 High-Capacity Input Module Specifications
Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch  <50 mΩ
Basic CJC Accuracy  0.6 °C

Accessories: Fluke 1586A Super-DAQ Precision Temperature Scanner

Temperature calibration (4)

  • 1586-2586 |High-Capacity Module without Relay Card
  • 1586-2586/C |High-Capacity Module without Relay Card, Accredited Calibration
  • 1586-2586-KIT | High-Capacity Module with Relay Card
  • 1586-2586-KIT/C High-Capacity Module with Relay Card, Accredited Calibration

Adapters and cables (5)

  • 1586-2588 |DAQ-STAQ Multiplexer without Adapter Card
  • 1586-2588/C | DAQ-STAQ Multiplexer without Adapter Card, Accredited Calibration
  • 1586-2588-KIT |DAQ-STAQ Mutiplexer, Adapter Card, Interface Cable
  • 1586-2588 DAQ-STAQ Multiplexer Kit
  • 1586-2588-CBL | DAQ-STAQ Multiplexer Interface Cable

No resources available for this product.

No reviews yet. Be the first to review this product!

Write a Review