Fluke 724 Temperature Calibrator
Versatile temperature calibration for demanding field and laboratory work
Fluke 724 is a versatile temperature calibrator designed for professional testing and calibration tasks, making Fluke 724 Temperature Calibrator Price in Bangladesh a relevant search topic for engineers and maintenance professionals. This multifunctional instrument supports temperature sourcing and measurement, helping technicians verify sensors, transmitters, switches, and related instrumentation efficiently. Its practical design makes it suitable for industrial plants, process facilities, maintenance environments, and calibration applications where dependable performance is essential.
The Fluke 724 combines temperature sourcing and measurement capabilities in a single portable instrument. This allows engineers to simulate temperature signals and compare them against the response of connected devices. Such functionality can simplify troubleshooting and calibration procedures by reducing the need to use multiple instruments during field service and maintenance work.
Designed for process instrumentation professionals, the Fluke 724 can support a wide range of temperature calibration activities. It is useful for checking temperature transmitters, switches, sensors, and other process devices. Its flexible functionality helps technicians perform verification tasks more efficiently while maintaining a consistent approach to measurement and signal simulation.
Portability is an important advantage when calibration work needs to be performed directly at industrial equipment. The Fluke 724 is designed for convenient field use, allowing technicians to carry out testing and troubleshooting close to the process installation. Its user-oriented interface helps streamline routine calibration tasks and makes instrument operation practical for experienced maintenance personnel.
The Fluke 724 is engineered for professionals who require dependable measurement and sourcing performance during calibration work. Consistent operation helps technicians identify discrepancies between expected and actual instrument responses. This can contribute to faster fault identification, improved maintenance decisions, and more efficient commissioning or verification procedures.
Fluke calibration equipment is developed with demanding industrial environments in mind. The Fluke 724 features a rugged professional design intended to withstand regular handling and field service conditions. Its portable construction makes it a practical choice for engineers who frequently move between control panels, process equipment, workshops, and calibration areas.
The Fluke 724 Temperature Calibrator is well suited to industrial maintenance, instrumentation testing, process control verification, and calibration workflows. Its combination of sourcing and measurement functions provides technicians with a convenient solution for working with temperature-related instrumentation. It can be integrated into established maintenance procedures where accurate and repeatable testing is required.
Choosing the Fluke 724 can provide engineers with a flexible and practical tool for temperature calibration and troubleshooting. Its multifunctional design reduces the complexity of field testing while supporting professional measurement practices. For technicians seeking a dependable calibrator for industrial instrumentation, the Fluke 724 offers a strong combination of versatility, usability, portability, and durable engineering.
| Measurement Accuracy | ||
| Voltage DC | 30.000 V | 0.02% + 2 counts (upper display) |
| 20.000 V | 0.02% + 2 counts (lower display) | |
| 100.00 mV | 0.02% + 2 counts | |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC | 24.000 mA | 0.02% + 2 counts |
| Resistance | 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
| 401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) | |
| 1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) | |
| Source Accuracy | ||
| Voltage DC | 100.00 mV | 0.02% + 2 counts |
| 10.000 V | 0.02% + 2 counts | |
| -10.00 mV to 75.00 mV | 0.025 % + 1 count (via TC connector) | |
| Resistance | 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
| 401 to 1500 Ω | 0.5 Ω (excitation current 0.05 to 0.8 mA) | |
| 1500 to 3200 Ω | 1 Ω (excitation current 0.05 to 0.4 mA) | |
| RTDs and Thermocouples | ||
| Measure accuracy | NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C | |
| PT-100 (393) | 0.3°C | |
| PT-100 (JIS) | 0.3°C | |
| PT-200 (385) | 0.2°C | |
| PT-500 (385) | 0.3°C | |
| PT-1000 (385) | 0.2°C | |
| Resolution | 0.1°C | |
| J | 0.7°C | |
| K | 0.8°C | |
| T | 0.8°C | |
| E | 0.7°C | |
| R | 1.8°C | |
| S | 1.5°C | |
| B | 1.4°C | |
| L | 0.7°C | |
| U | 0.75°C | |
| N | 0.9°C | |
| Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
| XK | 0.6°C | |
| BP | 1.2°C | |
| Source accuracy | NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C | |
| PT-100 (393) | 0.3°C | |
| PT-100 (JIS) | 0.3°C | |
| PT-200 (385) | 0.2°C | |
| PT-500 (385) | 0.3°C | |
| PT-1000 (385) | 0.2°C | |
| Resolution | 0.1°C | |
| Accuracy stated for 4-wire measurement. | ||
| J | 0.7°C | |
| K | 0.8°C | |
| T | 0.8°C | |
| E | 0.7°C | |
| R | 1.4°C | |
| S | 1.5°C | |
| B | 1.4°C | |
| L | 0.7°C | |
| U | 0.75°C | |
| N | 0.9°C | |
| Resolution | J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C | |
| XK | 0.6°C | |
| BP | 1.2°C | |
| Specifications | ||
| Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
| Loop power function | Voltage | 24 V |
| Accuracy | 10% | |
| Maximum current | 22 mA, short circuit protected | |
| Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Steps | 25% of range, 100% of range | |
| Environmental Specifications | ||
| Operating temperature | -10°C to 55°C | |
| Storage temperature | -20°C to 71°C | |
| Humidity (without condensation) | 90% | 10°C to 30°C |
| 75% | 30°C to 40°C | |
| 45% | 40°C to 50°C | |
| 35% | 50°C to 55°C | |
| Safety Specifications | ||
| Safety rating | CSA C22.2 No. 1010.1:1992 | |
| EMC | EN50082-1:1992 and EN55022:1994 Class B | |
| Mechanical and General Specifications | ||
| Size | 96 x 200 x 47 mm | |
| Weight | 650 g | |
| Batteries | Four AA alkaline batteries | |
| Warranty | Three years | |
| Battery life | 25 hours typical | |
| Shock and vibration | Random, 2 G, 5-500 Hz | |