Fluke 721 Pressure Calibration Instruments
Professional Pressure Calibration for Accurate Field Instrumentation
Fluke 721 Pressure Calibration Instruments are designed for professional pressure measurement and process calibration applications, and the Fluke 721 Pressure Calibration Instruments Price in Bangladesh is an important consideration for industries, laboratories, and instrumentation professionals seeking dependable calibration equipment. The Fluke 721 series provides a practical solution for verifying pressure instruments and supporting process measurement systems. Its portable design and professional calibration capabilities make it suitable for field service, maintenance, commissioning, and troubleshooting activities across a wide range of industrial environments.
The Fluke 721 is designed to provide reliable pressure measurement for calibration and verification tasks. Engineers can use the instrument with suitable pressure sources and reference procedures to evaluate the performance of compatible pressure devices. Accurate pressure measurement helps maintain dependable process monitoring and control. The calibrator can support technicians when checking pressure instruments during routine maintenance, commissioning, troubleshooting, and scheduled calibration activities.
Process instrumentation requires regular verification to maintain dependable measurement performance. The Fluke 721 can be incorporated into calibration procedures for suitable pressure instruments used in industrial processes. Technicians can compare measured pressure with an appropriate reference or apply controlled pressure conditions to assess instrument response. This makes the instrument useful for maintenance teams and calibration professionals working with process measurement systems.
The Fluke 721 features a portable design that makes it convenient for field service applications. Technicians can carry the calibrator to different areas of an industrial facility and perform suitable pressure measurement and verification tasks close to installed instruments. This can reduce the need to transport instruments back to a laboratory for every routine inspection. Its field-oriented design provides flexibility for engineers working across process plants, workshops, and maintenance areas.
The Fluke 721 can support the testing and verification of compatible pressure gauges, transmitters, and other pressure measurement devices. Engineers can use the instrument as part of a structured testing procedure to identify measurement deviations and assess instrument performance. This capability is useful for preventive maintenance and troubleshooting because potential measurement problems can be identified before they affect process monitoring or equipment operation.
Pressure measurement is important in many industries, including oil and gas, petrochemical processing, chemical manufacturing, power generation, utilities, manufacturing, and other process environments. The Fluke 721 can support suitable calibration and verification tasks in these applications. Its portable configuration allows field technicians to perform pressure measurement work where the instruments are installed, helping maintenance teams manage calibration activities more efficiently.
A professional pressure calibrator should integrate smoothly into established maintenance and calibration procedures. The Fluke 721 provides a practical platform for pressure measurement and process instrument verification. Technicians can use appropriate pressure sources, reference standards, and connections according to the requirements of the specific application. This organized approach can help improve testing efficiency and support consistent calibration practices across different industrial facilities.
Field calibration equipment is often exposed to frequent transportation, handling, and demanding working conditions. The Fluke 721 is designed for professional applications where portability and dependable operation are important. Proper handling, storage, inspection, and maintenance can help preserve its performance over time. Engineers should operate the instrument according to the manufacturer's recommendations and use suitable accessories and connections for each calibration application.
The Fluke 721 can help instrumentation engineers streamline pressure measurement and calibration activities. Its portable configuration allows technicians to perform suitable testing closer to the installation site, while its pressure measurement capabilities support systematic instrument verification. It can be useful for preventive maintenance, commissioning, troubleshooting, and routine calibration programs. A dedicated pressure calibration instrument can also help maintenance teams maintain better control over the performance of process measurement equipment.
Organizations searching for the Fluke 721 Pressure Calibration Instruments Price in Bangladesh can consider this equipment for industrial pressure calibration, process instrumentation maintenance, laboratory testing, and field service applications. Before selecting a pressure calibrator, engineers should evaluate the required pressure capability, measurement requirements, reference standards, connections, environmental conditions, and intended application. Proper technical assessment helps ensure that the selected instrument is suitable for the organization's calibration workflow.
The Fluke 721 Pressure Calibration Instruments provide a practical solution for professionals involved in pressure measurement, process calibration, and instrument verification. Their portable design and application-focused functionality make them useful for qualified engineers and technicians working in laboratory and industrial environments. When integrated into a properly managed calibration program and operated according to recommended procedures, the Fluke 721 can support dependable pressure testing, maintenance, and measurement verification.
| Specifications 1-Year | |||
| Fluke-721-1615 | Range | Resolution | Accuracy |
| Low pressure sensor | |||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
| Fluke-721-1630 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
| Fluke-721-1650 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
| Fluke-721-3615 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
| Fluke-721-3630 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
| Fluke-721-3650 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
| General Specifications | |||
| Instrument setup recall | Last used on power-up | ||
| Environmental | Operating temperature -10°C to +50°C Storage temperature (without batteries) -20°C to +60°C |
||
| Altitude | 2,000 m | ||
| Ingress protection | IP-40 | ||
| Power requirements | 6.0 V DC | ||
| Battery life | >35 hours, typical usage | ||
| Batteries required | (4) Standard AA cells | ||
| Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) | ||
| Weight | 03539 kg (1 lb 3 oz) | ||
| Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe | ||
| Electrical and Temperature Measurement 1-Year | |||
| Function | Range | Resolution | Accuracy |
| mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
| V DC measure | 0 to 30 V DC | 0.001 V | ±0.015% of rdg ±0.002 V |
| Temperature measure (RTD/ Ohms)1 | -40°C to 150°C (-40°F to 302°F) |
0.01°C, 0.01°F | ±0.015% of rdg ±0.02 ohms ±0.1°C (±0.2°F) ±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe accessory |
| Loop power supply | 24 V | N/A | 24 mA @ 24 V |
| 1. Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory | |||
| Temperature Effect | |||
| No effect on accuracy on all functions from 15°C to 35°C | |||
| Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | |||
| Available Pressure Engineering Units | |||
| psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F | |||
N/A
No resources available for this product.