Fluke 726 Precision Multifunction Calibrators
One Powerful Calibrator for Complete Process Instrumentation
Fluke 726 Precision Multifunction Calibrators is a versatile process calibration instrument, making the Fluke 726 Precision Multifunction Calibrators Price in Bangladesh a relevant search for engineers and technicians seeking reliable multifunction calibration equipment. Designed for demanding industrial and laboratory applications, it helps professionals measure and simulate process signals while supporting the calibration and troubleshooting of a wide range of process instruments.
The Fluke 726 is designed to support multiple calibration requirements within a single professional instrument. It helps technicians work with various process signals and measurement parameters, reducing the need to use separate instruments for different calibration tasks. This versatility makes it suitable for commissioning, preventive maintenance, troubleshooting, and routine instrument verification.
Reliable process control depends on accurate measurement and signal transmission. The Fluke 726 supports engineers in measuring and simulating process signals to evaluate the performance of connected instruments. Its versatile functionality helps technicians identify signal irregularities and verify that process instrumentation is operating correctly.
Troubleshooting instrumentation systems often requires more than basic measurement. The Fluke 726 provides useful calibration and diagnostic capabilities that help engineers investigate faults in process measurement circuits. By supporting both measurement and simulation tasks, it can make troubleshooting more efficient and help reduce unnecessary equipment downtime.
Process transmitters require regular verification to maintain dependable measurement and control. The Fluke 726 can assist technicians with transmitter calibration and performance checks across various process applications. It provides a practical platform for verifying instrument response and supporting accurate process measurement.
The Fluke 726 is suitable for field maintenance teams working in demanding industrial environments. Engineers can use it during installation, commissioning, preventive maintenance, inspection, and fault diagnosis. Its multifunction design helps technicians perform several calibration activities with a single professional tool.
A professional calibrator should provide flexible functionality without making routine testing unnecessarily complicated. The Fluke 726 is designed to support efficient operation, helping technicians access essential calibration and measurement functions during field and laboratory work. Its practical design supports organized and repeatable testing procedures.
Industrial calibration equipment must withstand frequent handling and demanding working conditions. The Fluke 726 is designed for professional applications with a durable construction suitable for regular maintenance and calibration activities. Its robust design makes it a practical choice for technicians who require dependable equipment in the field.
The Fluke 726 Precision Multifunction Calibrators can be used in manufacturing, chemical processing, pharmaceutical production, power generation, oil and gas, water treatment, and other process industries. It is particularly useful for professionals responsible for maintaining transmitters, sensors, process loops, and industrial instrumentation systems.
Using a multifunction calibrator can simplify the maintenance workflow by combining several important calibration capabilities into one instrument. The Fluke 726 helps engineers perform measurement, signal simulation, instrument verification, and troubleshooting tasks efficiently, supporting improved maintenance productivity and reliable process operation.
For instrumentation engineers, calibration technicians, and industrial maintenance professionals, the Fluke 726 offers a versatile solution for process instrument testing and calibration. Its multifunction capability, practical operation, durable construction, and field oriented design make it well suited for demanding calibration, commissioning, and troubleshooting applications.
| Measurement Accuracy | ||
| Voltage DC | 30.000 V | 0.01% + 2 mV (upper display) |
| 20.000 V | 0.01% + 2 mV (lower display) | |
| 90.00 mV | 0.01% + 10 μV | |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC | 24.000 mA | 0.01%+ 2 mA |
| Resistance | 0.0 to 4000.0 Ω | ± 0.015% |
| Frequency | 2.0 to 1000.0 CPM | 0.05% + 0.1 cpm |
| 1.0 to 1000.0 Hz | 0.05% + 0.1 Hz | |
| 1.00 to 15.00 kHz | 0.05% + 0.01 kHz | |
| Sensitivity | 1 V peak-to-peak-minimum | |
| Pressure |
Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
|
| Source Accuracy | ||
| Voltage DC | 100.00 mV | 0.01% + 10 μV |
| 20.000 V | 0.01% + 2 mV | |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC | 24.000 mA (Source) | 0.01% + 2 μA |
| 24.000 mA (Simulate) | 0.01% + 2 μA | |
| Resistance | Range, accuracy (percent of reading + floor) and excitation current | 5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA |
| 5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA | ||
| 400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA | ||
| 1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA | ||
| Frequency | 2.0 to 1000.0 CPM | 0.05% |
| 1.0 to 1000.0 Hz | 0.05% | |
| 1.0 to 10.0 kHz | 0.25% | |
| 10.0 to 15.0 kHz | 0.5% | |
| Waveform | 5 V p-p squarewave, -0.1 V offset | |
| RTDs and Thermocouples | ||
| Measure and source accuracy | Cu10 | 1.8°C |
| NI-120 | 0.15°C | |
| PT-100 (385) | 0.45°C | |
| PT-100 (392) | 0.35°C | |
| PT-100 (391-JIS) | 0.35°C | |
| PT-200 (385) | 0.95°C | |
| PT-500 (385) | 0.55°C | |
| PT-1000 (385) | 0.35°C | |
| RTD Resolution | 0.01°C (0.01°F) | |
| Cu10.01 C | 0.1°C (0.1°F) | |
| J | 0.4°C | |
| K | 0.5°C | |
| T | 0.4°C | |
| E | 0.4°C | |
| R | 1.4°C | |
| S | 1.4°C | |
| B | 1.4°C | |
| L | 0.45°C | |
| U | 0.45°C | |
| N | 0.6°C | |
| XK | 0.4°C | |
| BP | 1.1°C | |
| TC Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
| Specifications | ||
| Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
| Loop power function | Voltage | 24 V |
| Accuracy | 10% | |
| Maximum current | 22 mA, short circuit protected | |
| Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
| Steps | 25% of range, 100% of range | |
| Environmental Specifications | ||
| Operating temperature | -10°C to +55°C | |
| Storage temperature | -20°C to +71°C | |
| Operating altitude | 3000 m | |
| Safety Specifications | ||
| Agency approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 | |
| Mechanical and General Specifications | ||
| Size | 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in) | |
| Weight | 650 g (23 oz) | |
| Batteries | 4 AA alkaline batteries | |
| Battery replacement | Separate battery compartment, accessible without breaking calibration seal | |
| Side port connections | Pressure module connector, also used for remote real-time programming | |
No resources available for this product.
No reviews yet. Be the first to review this product!