Fluke 750P Series Pressure Modules
Precision Pressure Measurement for Professional Calibration
Fluke 750P Series Pressure Modules are precision pressure measurement accessories designed for professional calibration applications, and the Fluke 750P Series Pressure Modules Price in Bangladesh is an important consideration for calibration laboratories, instrumentation engineers, and industrial maintenance teams. These modules are designed to work with compatible Fluke documenting process calibrators and multifunction calibration instruments, providing convenient pressure measurement for instrument testing and verification. Their modular approach allows technicians to select an appropriate pressure module for a particular application while keeping the overall calibration setup flexible.
The Fluke 750P Series provides pressure measurement capabilities for a broad range of professional calibration tasks. Each module is designed to convert applied pressure into an electrical signal that can be interpreted by compatible Fluke calibration equipment. This allows technicians to perform pressure measurement and verification without relying on a dedicated pressure measuring instrument for every application. The modular design is particularly useful when calibration teams need to work with different pressure ranges or measurement requirements.
A key benefit of the Fluke 750P Series Pressure Modules is their integration with compatible Fluke calibration instruments. When connected to a supported calibrator, the pressure module can become part of a complete pressure measurement and calibration system. This allows engineers to use a familiar calibration platform while changing pressure measurement capability through interchangeable modules. Such flexibility can simplify equipment management for laboratories and field service teams handling different instrumentation requirements.
Pressure modules can be used for a variety of calibration and verification tasks involving compatible pressure instruments. Engineers may use the Fluke 750P Series for checking pressure transmitters, gauges, switches, and other measurement devices according to the requirements of the application. They can also support troubleshooting and preventive maintenance activities where pressure measurement is required. Selecting the correct module for the intended application is essential for obtaining suitable measurement performance.
The modular and portable nature of the Fluke 750P Series makes it useful for field calibration and industrial maintenance. Technicians can carry compatible pressure modules with their calibration equipment and select the appropriate module when working with different pressure instruments. This approach can reduce the need to transport multiple dedicated pressure measurement devices. It is especially useful for maintenance teams working across process plants, manufacturing facilities, utilities, and instrumentation service environments.
Reliable pressure measurement is essential for many process control systems. The Fluke 750P Series Pressure Modules can support calibration procedures for suitable process instruments by providing pressure measurement through compatible Fluke calibrators. Technicians can use the resulting measurement as part of a comparison or verification process. This can help identify instrument deviations and support maintenance decisions while contributing to a structured calibration program.
The interchangeable nature of pressure modules provides flexibility when calibration requirements change. Instead of using a single pressure measuring device for every task, technicians can select a compatible module appropriate to the application. This modular approach can help organizations build a more adaptable calibration toolkit. It also allows calibration teams to expand their pressure measurement capabilities as new testing requirements arise.
Pressure modules used in industrial and field environments need to withstand regular handling, connection, and transportation. The Fluke 750P Series is designed for professional calibration applications and provides a practical construction suitable for routine use. Proper handling, storage, inspection, and calibration are important for maintaining measurement performance. Users should always operate each pressure module within its specified application limits and follow the manufacturer's recommendations.
The Fluke 750P Series can help calibration engineers create flexible pressure measurement systems tailored to specific testing requirements. Its compatibility with supported Fluke calibrators allows technicians to integrate pressure measurement into broader calibration workflows. The modules can support routine verification, troubleshooting, preventive maintenance, commissioning, and laboratory calibration. Their modular format can also help reduce unnecessary duplication of pressure measurement equipment within a calibration department.
Organizations searching for the Fluke 750P Series Pressure Modules Price in Bangladesh can consider these modules for industrial calibration, process instrumentation testing, laboratory measurement, and field service applications. Before selecting a pressure module, engineers should review the required pressure range, measurement type, compatibility with the intended Fluke calibrator, connection requirements, and application environment. Choosing the appropriate module is essential for achieving reliable and suitable pressure measurement results.
The Fluke 750P Series Pressure Modules provide a flexible approach to pressure measurement and calibration when used with compatible Fluke calibration equipment. Their modular design, professional construction, and suitability for field and laboratory applications make them valuable tools for instrumentation engineers and calibration technicians. By selecting appropriate modules for individual testing requirements, organizations can develop an efficient pressure calibration system that supports reliable instrument verification and maintenance.
| Differential Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750P00 | 0 to 1 inH2O (0 to 2.5 mBar) | 30X | Dry air | Dry air | |
| 750P3IN | 0 to 3 Inch H2O (0 to 7.5 mbar) | 10X | Dry air | Dry air | |
| 750P5IN | 0 to 5 Inch H2O (0 to 12.5 mbar) | 6X | Dry air | Dry air | |
| 750P017 | 0 to 10 inH2O (0 to 25 mBar) | 3X | Dry air | Dry air | |
| 750P02 | 0 to 1 psi (0 to 70 mBar) | 3X | Dry air | Dry air | |
| 750P22 | 0 to 1 psi (0 to 70 mBar) | 3X | 316 SS | Dry air | |
| 750P03 | 0 to 5 psi (0 to 350 mBar) | 3X | Dry air | Dry air | |
| 750P23 | 0 to 5 psi (0 to 350 mBar) | 4X | 316 SS | Dry air | |
| 750P04 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
| 750P247 | 0 to 15 psi (0 to 1 bar) | 4X | 316 SS | Dry air | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750P00 | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
| 750P3IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
| 750P5IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
| 750P017 | ±0.1% | ±0.2% | ±0.3% | ±0.15% | ±0.25% |
| 750P02 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
| 750P22 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
| 750P03 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
| 750P23 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
| 750P04 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P247 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| Gage Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750P057 | 0 to 30 psi (0 to 2 bar) | 4X | 316 SS | N/A | |
| 750P067 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | N/A | |
| 750P277 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | N/A | |
| 750P07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | N/A | |
| 750P08 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | N/A | |
| 750P097 | 0 to 1500 psi (0 to 100 bar) | 3X | 316 SS | N/A | |
| 750P2000 | 0 to 2000 psi (0 to 140 bar) | 3X | 316 SS | N/A | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750P057 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P067 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P277 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P07 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P08 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P097 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
| 750P2000 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
| High Pressure Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750P29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | N/A | |
| 750P30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | N/A | |
| 750P31 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | N/A | |
| Model | Reference uncertainty4
td>
Total uncertainty |
1-year (15-35°C) Total uncertainty |
1-year1 Total uncertainty |
6-month (15-35°C) Total uncertainty |
6-month1 |
| 750P29 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P30 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| 750P31 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
| Absolute Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750PA3 | 0 to 5 psia (0 to 350 mBar) | 4X | 316 SS | N/A | |
| 750PA47 | 0 to 15 psia (0 to 1 bar) | 4X | 316 SS | N/A | |
| 750PA5 | 0 to 30 psia (0 to 2 bar) | 4X | 316 SS | N/A | |
| 750PA6 | 0 to 100 psia (0 to 7 bar) | 4X | 316 SS | N/A | |
| 750PA27 | 0 to 300 psia (0 to 20 bar) | 4X | 316 SS | N/A | |
| 750PA7 | 0 to 500 psia (0 to 35 bar) | 4X | 316 SS | N/A | |
| 750PA8 | 0 to 1000 psia (0 to 70 bar) | 3X | 316 SS | N/A | |
| 750PA9 | 0 to 1500 psia (0 to 100 bar) | 3X | 316 SS | N/A | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750PA3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA47 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA5 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA6 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA27 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA7 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA8 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PA9 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| Vacuum Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750PV3 | -5 psi (-350 mBar) | 4X | 316 SS | Dry air | |
| 750PV4 | -15 psi (-1 bar) | 4X | 316 SS | Dry air | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750PV3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PV4 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| Dual Range Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750PD2 | -1 to 1 psi (-70 to 70 mBar) | 4X | 316 SS | Dry air | |
| 750PD3 | -5 to 5 psi (-350 to 350 mBar) | 4X | 316 SS | Dry air | |
| 750PD10 | -10 to 10 psi (-700 to 700 mBar) | 4X | 316 SS | Dry air | |
| 750PD4 | -15 to 15 psi (-1 to 1 bar) | 4X | 316 SS | Dry air | |
| 750PD5 | -15 to 30 psi (-1 to 2 bar) | 4X | 316 SS | — | |
| 750PD50 | -15 to 50 psi (-1 to 3.5 bar) | 4X | 316 SS | — | |
| 750PD6 | -15 to 100 psi (-1 to 7 bar) | 4X | 316 SS | — | |
| 750PD7 | -15 to 200 psi (-1 to 14 bar) | 4X | 316 SS | — | |
| 750PD27 | -15 to 300 psi (-1 to 20 bar) | 4X | 316 SS | — | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750PD2 | ±0.05% | ±0.1% | ±0.15% | ±0.075% | |
| 750PD3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
| 750PD10 | ±0.025% | ±0.05% | ±0.07% | ±0.04% | ±0.06% |
| 750PD4 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ± 0.04% |
| 750PD5 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
| 750PD50 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
| 750PD6 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
| 750PD7 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
| 750PD27 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
| Reference Module Specifications | |||||
| Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
| 750R045 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
| 750R065 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | — | |
| 750R27 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | — | |
| 750R07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | — | |
| 750R085 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | — | |
| 750R29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | — | |
| 750R30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | — | |
| 750R315 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | — | |
| 750RD5 | -15 to 30 psi (-1 to 2 bar) | 4X | Dry air | — | |
| 750RD65 | -12 to 100 psi (-0.8 to 7 bar) | 4X | 316 SS | — | |
| 750RD27 | -12 to 300 psi (-0.8 to 20 bar) | 4X | 316 SS | — | |
| Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) |
Total uncertainty 1-year1 |
Total uncertainty 6-month (15-35°C) |
Total uncertainty 6-month1 |
| 750R045 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R065 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R07 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R085 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R29 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R30 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750R315 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750RD5 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750RD65 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 750RD27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
| 1. Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one year interval. No 6 month specification available for range -10°C to 0°C. 2. “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel. 3. Specifications % of Full Span unless otherwise noted. 4. Reference Uncertainty is the specification for as left data for 24 hours. 5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification. 6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure. 7. Intrinsically Safe pressure module available in this pressure range. |
|||||
Adapters and cables (1)
N/A
No reviews yet. Be the first to review this product!