Fluke Calibration 9144 Metrology Well

Precision Temperature Calibration for Professional Metrology

Fluke Calibration 9144 Metrology Well
Brand: Fluke
Category: Temperature Calibrators
Availability: Ready Stock
Always authentic product We only sell 100% authentic products
Fast Shipping Receive products in amazing time.
Easy returns Return policy that let you shop at ease
Secure shopping Your data is always protected

Fluke Calibration 9144 Metrology Well Price in Bangladesh

Fluke Calibration 9144 Metrology Well is designed for professional temperature calibration applications, making the Fluke Calibration 9144 Metrology Well Price in Bangladesh an important consideration for calibration laboratories, industrial facilities, and instrumentation professionals. This metrology well provides a controlled thermal environment for verifying temperature sensors and other compatible measurement instruments. Its professional design supports reliable calibration workflows where temperature stability, repeatability, and measurement confidence are essential.

Professional Temperature Calibration

Temperature measurement plays an important role in industrial processes, quality control, research, and equipment maintenance. Even small measurement deviations can influence process performance and product quality. A professional metrology well provides a controlled temperature source that allows technicians to compare a device under test against an appropriate reference standard. The Fluke Calibration 9144 is developed for users who require dependable temperature calibration equipment for laboratory and industrial applications.

Stable Thermal Environment

A stable temperature environment is fundamental to accurate calibration. The Fluke Calibration 9144 Metrology Well is engineered to provide controlled thermal conditions that support repeatable calibration procedures. By maintaining the required temperature environment around suitable sensors, the instrument helps technicians obtain more consistent measurement results. Stable operation is particularly valuable in calibration laboratories where repeatability and measurement uncertainty must be carefully managed.

Suitable for Temperature Sensors

The metrology well can be used for calibrating suitable temperature sensors and probes across professional measurement applications. Depending on the calibration procedure, technicians can place the sensing portion of the device under test into the appropriate well position and compare its reading with a calibrated reference. This approach provides a practical way to identify measurement deviations and verify whether temperature instruments continue to perform within the required specifications.

Laboratory Calibration Applications

Calibration laboratories require reliable equipment capable of supporting systematic measurement procedures. The Fluke Calibration 9144 Metrology Well can be integrated into laboratory workflows for temperature verification and calibration. Its professional construction and controlled thermal operation make it suitable for calibration engineers and laboratory technicians who need dependable equipment for routine temperature measurement activities. It can also complement reference thermometers and other precision instruments used within a laboratory calibration system.

Industrial Instrumentation Support

Temperature sensors are commonly installed in manufacturing systems, process equipment, HVAC systems, energy facilities, pharmaceutical production, food processing, and other industrial environments. Regular verification helps organizations maintain confidence in these measurement devices. A suitable metrology well provides a controlled reference environment for checking compatible sensors before they are returned to service. This can contribute to better process monitoring, quality assurance, and preventive maintenance practices.

Practical Metrology Solution

The Fluke Calibration 9144 is intended to support professional metrology activities where controlled temperature generation is required. Its design helps technicians establish a repeatable calibration environment without depending solely on process conditions. This makes the equipment useful for laboratories and service teams that need a dedicated temperature source for calibration work. A well-planned calibration procedure can improve measurement consistency and provide useful documentation for quality management systems.

Measurement Confidence and Repeatability

Reliable calibration requires more than obtaining a temperature reading. The reference environment, test procedure, sensor placement, stabilization time, and reference instrument all influence the final result. A professional metrology well helps create controlled conditions for these activities. The Fluke Calibration 9144 can therefore support calibration practices designed around repeatability and measurement confidence, particularly when operated according to appropriate procedures and manufacturer recommendations.

Application in Bangladesh

Industrial organizations and calibration service providers in Bangladesh use temperature measurement equipment across many sectors. Manufacturing plants, laboratories, pharmaceutical facilities, power plants, food processing companies, engineering service providers, and instrumentation teams can benefit from professional temperature calibration solutions. The Fluke Calibration 9144 Metrology Well can be considered where a controlled and dependable temperature source is required for verifying suitable temperature measurement instruments.

User Friendly Professional Design

Calibration equipment needs to be practical for technicians who perform measurement tasks regularly. A well-designed metrology instrument should provide straightforward operation while supporting the technical requirements of professional calibration. The Fluke Calibration 9144 is developed for users who work with temperature measurement and metrology applications. Its professional design can help technicians incorporate temperature calibration into established laboratory or field service procedures.

Durability and Long Term Reliability

Calibration equipment is frequently used in demanding technical environments, making construction quality and proper maintenance important considerations. Correct operating procedures, regular inspection, appropriate storage, and recommended servicing can help maintain reliable performance over the service life of the instrument. Organizations should also follow established calibration schedules to ensure that the metrology well and associated reference equipment continue to provide dependable measurement support.

Choosing a Metrology Well

When selecting a metrology well, users should evaluate the required calibration range, sensor dimensions, stability requirements, measurement uncertainty, reference standards, and intended application. The type of temperature instruments being calibrated should also be considered. Understanding these requirements helps calibration professionals select equipment that fits their workflow rather than choosing a temperature source based only on general specifications. Proper selection can improve efficiency and support more consistent calibration results.

Why Choose Fluke Calibration 9144

The Fluke Calibration 9144 Metrology Well offers a professional approach to temperature calibration where controlled thermal conditions are required. It is suitable for calibration laboratories, industrial instrumentation departments, quality assurance teams, and technical service organizations. Its focus on stable temperature control and professional metrology applications makes it a valuable tool for organizations that depend on accurate and repeatable temperature measurements.

Conclusion

The Fluke Calibration 9144 Metrology Well provides a practical solution for professional temperature calibration and verification through the temeprature calibrator. Its controlled thermal environment supports reliable testing of suitable te

mperature sensors and measurement instruments while helping technicians maintain consistent calibration procedures. For calibration laboratories, industrial facilities, and engineering organizations in Bangladesh, the 9144 can be a valuable addition to a professional temperature measurement and quality assurance system.

Key Features: Fluke Calibration 9144 Metrology Well

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

Specifications: Fluke Calibration 9144 Metrology Well

Base Unit Specifications
Temperature range at 23°C 50°C to 660°C (122°F to 1220°F)
Display accuracy ±0.35°C at 50°C
±0.35°C at 420°C
±0.5°C at 660°C
Stability ±0.03°C at 50°C
±0.04°C at 420°C
±0.05°C at 660°C
Axial uniformity at 40 mm (1.6 in) ±0.05°C at 50°C
±0.35°C at 420°C
±0.5°C at 660°C
Radial uniformity ±0.02°C at 50°C
±0.05°C at 420°C
±0.10°C at 660°C
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ±0.015°C at 50°C
±0.025°C at 420°C 
±0.035°C at 660°C
Hysteresis 0.1
Operating conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental conditions (for all specifications except temperature range) 13°C to 33°C
Immersion (well) depth 150 mm (5.9 in)
Insert OD 24.4 mm (0.96 in)
Heating time 15 min: 50°C to 660°C
Cooling time 25 min: 660°C to 100°C
35 min: 660°C to 50°C
Resolution 0.01°
Display LCD, °C or °F user-selectable
Size (H x W x D) 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight 7.7 kg (17 lb)
Power requirements 100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Computer interface RS-232 interface 
Calibration NVLAP accredited calibration included
Automation Use the 1586A Super-DAQ to automate temperature sensor calibration
-P Specifications
Built-in reference thermometer readout accuracy (4-wire reference probe)1 ±0.010°C at -25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 150°C
±0.030°C at 200°C
±0.040°C at 350°C
±0.050°C at 420°C
±0.070°C at 660°C
Reference resistance range 0 ohms to 400 ohms
Reference resistance accuracy2 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizations  ITS-90, CVD, IEC-751, Resistance
Reference measurement capability 4-wire
Reference probe connection 6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracy NI-120: ±0.015°C at 0°C
PT-100 (385): ±0.02°C at 0°C
PT-100 (3926): ±0.02°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range 0 ohms to 400 ohms
RTD resistance accuracy2 25 ohms to 400 ohms: ±80 ppm of reading
0 ohms to 25 ohms: ±0.002 ohms
RTD characterizations PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD measurement capability 4-wire RTD (2-,3-wire RTD w/ Jumpers only)
RTD connection 4 terminal input
Built-in TC thermometer readout accuracy Type J: ±0.7°C at 660°C
Type K: ±0.8°C at 660°C
Type T: ±0.8°C at 400°C
Type E: ±0.7°C at 660°C
Type R: ±1.4°C at 660°C
Type S: ±1.5°C at 660°C
Type M: ±1.4°C at 660°C
Type L: ±0.7°C at 660°C
Type U: ±0.75°C at 600°C
Type N: ±0.9°C at 660°C
Type C: ±1.1°C at 660°C
TC millivolt range –10 mV to 75 mV
Voltage accuracy 0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy ±0.35°C (ambient of 13°C to 33°C)
TC connection Small connectors
Built-in mA readout accuracy 0.02% of reading + 2 mV
mA range Cal 4-22 mA, Spec 4-24 mA
mA connection 2 terminal input
Loop power function 24 V DC loop power
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C) ±0.005% of range per°C

Accessories: Fluke Calibration 9144 Metrology Well

Temperature probes (1)

  • 9142-4 Field Metrology Wells Carrying Case

Calibration inserts (10)

  • 9144-INSA | Insert “A” 9144, Imperial Misc Holes
  • 9144-INSB | Insert “B” 9144, Imperial Comparison Holes
  • 9144-INSC | Insert “C” 9144, 0.25-inch Holes
  • 9144-INSD | Insert “D” 9144, Metric Comparison Holes
  • 9144-INSE | Insert “E” 9144, Metric Misc Holes w/0.25-inch Hole
  • 9144-INSY | Insert Custom 9144
  • 9144-INST | Insert, Test, 9144
  • 9144-INSG | Insert, G, 9144, EA test
  • 9144-INSF | Insert “F” 9144, Metric Comparison Misc Holes w/0.25-inch Hole
  • 9144-INSZ | Insert “Z” 9144, Blank

Adapters and cables (1)

  • HART DRYWELL CABLE | An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate

No resources available for this product.

No reviews yet. Be the first to review this product!

Write a Review