Hioki 3169 Clamp On Power Hitester
Reliable Clamp On Power Analysis for Professional Applications
Hioki 3169 Clamp On Power Hitester is designed to deliver precise electrical measurement and comprehensive power analysis, making Hioki 3169 Clamp On Power Hitester Price in Bangladesh a popular search among engineers, maintenance professionals, and energy auditors seeking a dependable power monitoring solution. Developed for industrial, commercial, and utility applications, this professional instrument helps evaluate electrical system performance, identify energy inefficiencies, and support effective preventive maintenance programs.
The Hioki 3169 provides accurate monitoring of essential electrical parameters, including voltage, current, active power, reactive power, apparent power, power factor, frequency, and energy consumption. Its advanced measurement functions enable engineers to assess electrical system performance with confidence, supporting detailed diagnostics and reliable operational analysis across various applications.
The clamp on measurement design allows electrical testing without disconnecting conductors or interrupting system operation. This non intrusive approach enhances operator safety while simplifying installation and reducing inspection time. Engineers and technicians can perform routine measurements efficiently, making the Hioki 3169 an excellent choice for maintenance, troubleshooting, and energy management tasks.
Engineered for professional field use, the Hioki 3169 features a rugged construction capable of withstanding challenging industrial conditions. Its durable housing ensures dependable performance in manufacturing facilities, commercial buildings, utility installations, processing plants, and infrastructure maintenance projects. The reliable design supports continuous operation during demanding inspection activities.
The intuitive interface presents measurement data in a clear and organized format, enabling maintenance personnel to analyze electrical performance quickly. Easy navigation and efficient data presentation reduce diagnostic time while supporting informed maintenance decisions. The streamlined workflow increases productivity during inspections and improves overall maintenance efficiency.
The Hioki 3169 helps maintenance teams identify excessive energy consumption, abnormal electrical loads, and developing power quality issues before they become serious operational concerns. Continuous monitoring supports predictive maintenance strategies, improves equipment reliability, and contributes to more efficient energy management across industrial and commercial facilities.
The Hioki 3169 Clamp On Power Hitester is suitable for manufacturing plants, commercial buildings, utility services, renewable energy systems, facility management, and industrial maintenance operations. Its versatile measurement capabilities support energy audits, electrical commissioning, equipment diagnostics, preventive maintenance, and long term system performance evaluation.
The Hioki 3169 combines precision measurement, advanced analytical capability, and durable construction to deliver dependable performance in demanding electrical applications. Its reliable operation, comprehensive diagnostic functions, and efficient clamp on design make it an essential instrument for engineers seeking accurate power analysis and improved electrical system reliability.
| Measurement line & number of circuits | Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line |
|---|---|
| Measurement items | Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order) |
| Measurement range | [Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line) |
| Basic accuracy | AC Voltage: ±0.2 % rdg. ±0.1 % f.s. AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1) Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models) |
| Measurement method | Digital sampling, PLL synchronization or 50/60 Hz fixed clock |
| Display refresh rate | 2 times /sec (except when a PC card accessing, or RS-232C communications) |
| Data save interval | Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only) |
| Frequency characteristics | Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform) |
| Other functions | Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.) |
| Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. |
| Dimensions and mass | 210 mm (8.27 in)W × 160 mm (6.30 in)H × 60 mm (2.36 in)D, 1.2 kg (42.3 oz) |
No resources available for this product.