Hioki MR8827 Memory Hicorder
Advanced Memory Hicorder for Reliable Waveform Analysis
Hioki MR8827 Memory Hicorder is a professional waveform recording instrument, and the Hioki MR8827 Memory Hicorder Price in Bangladesh is relevant for engineers looking for a dependable solution for advanced electrical measurement and signal analysis. Designed for demanding engineering applications, the MR8827 provides a flexible platform for recording electrical waveforms and analyzing dynamic signal behavior. Its application-oriented design makes it suitable for industrial testing, equipment troubleshooting, research, development, maintenance, and technical evaluation where reliable measurement data is essential.
The Hioki MR8827 is designed to support detailed waveform recording for a wide range of electrical and electronic measurement applications. Engineers can configure the measurement system according to the characteristics of the signals being investigated and the requirements of the testing environment. Recording actual waveforms provides useful information about changing electrical conditions and helps users examine system behavior more effectively. This capability is particularly valuable when investigating events that may not be clearly identified through conventional point measurement methods.
Accurate signal analysis plays an important role in electrical troubleshooting, equipment evaluation, and research. The Hioki MR8827 provides a dedicated platform for capturing measurement data and examining waveform characteristics. Engineers can use recorded information to investigate abnormal signal behavior, switching conditions, transient phenomena, and equipment performance. Detailed waveform analysis can help technical teams understand the relationship between different electrical signals and support more systematic investigation of complex measurement conditions.
The modular architecture of the Hioki MR8827 provides flexibility for different measurement applications. Engineering projects can involve different signal types and measurement requirements, so the ability to configure an instrument according to the application is highly useful. This approach allows users to develop a measurement setup suited to laboratory testing, industrial diagnostics, product development, or equipment evaluation. The flexible architecture also makes the Memory Hicorder suitable for organizations that need a versatile measurement platform for different technical projects.
The Hioki MR8827 Memory Hicorder can be used for troubleshooting electrical and electronic systems in industrial environments. Engineers can record operating waveforms to investigate unexpected equipment behavior, intermittent faults, switching issues, and other electrical abnormalities. Having detailed waveform records can make it easier to compare normal and abnormal operating conditions and identify areas requiring further investigation. This makes the instrument useful for maintenance teams, commissioning engineers, electrical specialists, and technical service providers.
Research and development applications often require reliable waveform acquisition under changing test conditions. The Hioki MR8827 can support engineers during experimental testing, product development, design verification, and performance evaluation. Recorded measurement data can be reviewed to understand system responses and validate engineering assumptions. Its flexible measurement capabilities make it suitable for technical environments where engineers need detailed electrical information during the development or evaluation of equipment and systems.
Professional measurement equipment must provide stable and dependable operation during repeated testing. The Hioki MR8827 is designed for engineering environments where waveform recording and signal analysis are important parts of the measurement process. Its professional design supports practical use in laboratories, industrial facilities, testing centers, and engineering service environments. With suitable measurement modules and accessories, users can develop application-specific configurations for different testing requirements.
Electrical diagnostics often require more than a single measurement taken at a specific moment. Recording signal behavior over the required measurement period can provide a more complete understanding of how equipment operates. The Hioki MR8827 allows engineers to examine recorded waveform information when investigating complex electrical conditions. This can support fault diagnosis, equipment verification, preventive maintenance, commissioning, and performance assessment while providing useful technical evidence for engineering decisions.
The Hioki MR8827 Memory Hicorder can be a valuable measurement solution for industrial companies, testing laboratories, engineering consultants, research organizations, educational institutions, and technical service providers in Bangladesh. Its flexible waveform recording capability allows it to be applied to different electrical testing requirements. Engineers can use the instrument for equipment diagnostics, research, development, commissioning, maintenance, and technical evaluation where dependable waveform information is required.
The Hioki MR8827 combines flexible measurement configuration, waveform recording, and signal analysis capabilities in a professional engineering platform. Its application-focused design helps users capture useful electrical information and investigate dynamic system behavior more effectively. For engineers who require a versatile Memory Hicorder for industrial testing, research, troubleshooting, or equipment evaluation, the MR8827 provides a dependable platform for obtaining meaningful measurement data and supporting informed technical analysis.
Accuracy guaranteed: 1 year
| Max. Number of channels | 32 ch analog + 32 ch logic, or 28 ch analog + 64 ch logic (when use with built-in logic input + plug-in logic unit 8973 × 2) |
|---|---|
| Number of slots | 16 slots (Max. 16) |
| Number of logic channels | 32 ch logic (logic probe terminal GND share a common GND with chassis) Built-in logic input not available when using DVM Unit MR8990 on slots 1, 2, 9, or 10. [Limitation on using built-in logic input] (with logic measurement ON) • Measurement resolution on slots 1, 2, 9, and slot 10 is limited up to 12 bits • Cannot use Frequency Unit 8970 on slots 1, 2, 9, or 10 |
| Measurement ranges (20 div full-scale) | [Analog Unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D) [High Resolution Unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D) |
| Max. allowable input | 400 V DC (using the 8966/8968) |
| Frequency characteristics | DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968) |
| Time axis (Memory function) | 5 µs to 5 min/div, 26 ranges, at 100 points/div resolution |
| Measurement functions | Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT |
| Other functions | Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function) |
| Memory capacity | 128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory |
| Data storage media | USB memory stick, CF card, Built-in SSD unit (option, 128GB) *Approx. 125 sec. when saving 100 MB of data *Data of 100 MB in size can record 16,000 div waveforms across 32 channels. |
| Printing | [Built-in A4-size printer option]: 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s |
| Display | 10.4 inch TFT color LCD (SVGA, 800 × 600 dots) |
| External interfaces | LAN: 100BASE-TX, USB 2.0 series A receptacle 2 port (for USB memory, mouse) USB 2.0 series B receptacle (for communication with PC, mass storage) |
| Power supply | 100 V to 240 V AC, 50/60 Hz (220 VA max., when using printer: 350 VA max.) |
| Dimensions and mass | 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D (including protruding parts except handle), 12.6 kg (444.4 oz) (main unit only) |
| Included accessories | Instruction manual ×1, Power cord ×1, Application disk (CD-R) ×1, Input cord label ×1, Printer paper ×1 (when ordering printer unit), Roll paper attachment ×2 (when ordering printer unit) |
| Compatible models | LabVIEW | MATLAB script | ||||
|---|---|---|---|---|---|---|
| MR8827 | Available | |||||
N/A
No resources available for this product.
No reviews yet. Be the first to review this product!