Fluke 5730A High Performance Multifunction Calibrator
High Performance Calibration for Precision Measurement
Fluke 5730A is an advanced multifunction calibration solution, and the Fluke 5730A High Performance Multifunction Calibrator Price in Bangladesh is relevant for laboratories and technical organizations seeking dependable equipment for demanding electrical calibration applications. Designed for high performance calibration environments, it provides a versatile platform for verifying precision measurement instruments and supporting consistent calibration practices.
The Fluke 5730A is designed to support professional calibration requirements across a broad range of electrical measurement applications. Its multifunction capability allows calibration professionals to work with different types of precision instruments through an integrated calibration platform. This approach can simplify laboratory operations while supporting accurate and repeatable testing procedures.
Reliable electrical output is essential when calibrating high accuracy measurement equipment. The Fluke 5730A provides controlled and stable signals to support verification and adjustment procedures. Consistent output performance helps calibration technicians compare instrument readings against trusted reference values and maintain confidence in the results generated during professional calibration activities.
Modern calibration laboratories require equipment capable of supporting increasingly demanding measurement applications. The Fluke 5730A is engineered for precision focused environments where stability, repeatability, and dependable operation are important. Its professional design makes it suitable for calibration specialists who need a reliable platform for maintaining the performance of advanced electrical measurement instruments.
A multifunction calibrator can help laboratories streamline their daily calibration activities by combining multiple calibration functions within a single system. The Fluke 5730A supports an efficient workflow by providing a centralized solution for various electrical calibration tasks. This can reduce equipment handling requirements and help technicians maintain a more organized calibration process.
The Fluke 5730A High Performance Multifunction Calibrator is suitable for professional calibration laboratories, electrical test facilities, manufacturing environments, research organizations, and technical service departments. It can support calibration activities where precision electrical output and dependable reference performance are essential for verifying measurement instruments.
Maintaining measurement traceability requires dependable calibration equipment and controlled testing procedures. The Fluke 5730A can contribute to a structured calibration environment by providing a reliable source for electrical measurement verification. Proper use of multifunction calibration equipment helps organizations maintain consistent testing practices and support confidence in the accuracy of their measurement systems.
Professional calibration equipment must be capable of supporting regular use in demanding technical environments. The Fluke 5730A is designed with professional engineering considerations focused on dependable operation and practical laboratory use. Its robust design supports repeated calibration activities while helping technical teams maintain consistent performance throughout their measurement and verification workflows.
The Fluke 5730A combines multifunction capability with precision focused calibration performance, making it a suitable solution for organizations working with sophisticated electrical measurement equipment. Its broad application potential allows calibration professionals to manage different testing requirements through an integrated system while maintaining a consistent approach to electrical calibration.
Organizations searching for the Fluke 5730A High Performance Multifunction Calibrator Price in Bangladesh may require a professional calibration system capable of supporting demanding measurement environments. The Fluke 5730A offers a dependable solution for laboratories and technical organizations focused on precision, repeatability, efficient workflow, and long term calibration performance.
Accurate measurement depends on reliable instruments and a well controlled calibration process. The Fluke 5730A provides a professional platform for calibration specialists who require versatile functionality, stable electrical output, and dependable performance. Its advanced calibration capabilities make it suitable for organizations committed to maintaining high standards of electrical measurement and laboratory quality.
| Technical Specifications | ||
| Voltage DC | Range | 0 to ±1100 V |
| Best 1 Year, 95% Specification | 3.5 ppm + 2.5 µV | |
| Voltage AC | Range | 22 µV to 1100V |
| 10 Hz to 1 MHz | ||
| Best 1 Year, 95% Specification: | 42 ppm + 8 µV | |
| Resistance | Range | 0 to 100 MΩ, 18 values in x1 and x1.9 |
| Best 1 Year, 95% Specification | 6.5 ppm | |
| Current DC | Range | 0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A) |
| Best 1 Year, 95% Specification | 35 ppm + 7 nA | |
| Current AC | Range | 9 µA to 2.2A, 10 Hz to 10 kHz (9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A) |
| Best 1 Year, 95% Specification | 103 ppm + 8 nA | |
| Wideband ac Voltage option | Range | 300 µV to 3.5V |
| 10 Hz to 50 MHz | ||
| Best 1 Year, 99% Specification | 0.4% + 500 µV | |
| General Specifications | ||
| Warm up time | Twice the time since last warmed up, to a maximum of 30 minutes | |
| Settling time | Less than 5 seconds for all functions and ranges except as noted | |
| Standard interfaces | IEEE-488 (GPIB), RS-232, USB 2.0 Device, Ethernet, 5725A, 52120A, phase lock in (BNC), phase reference out (BNC) | |
| Temperature performance | Operating | 0 °C to 50 °C |
| Calibration:15 °C to 35 °C | 15 °C to 35 °C | |
| Storage | -40 °C to 75 °C | |
| Operating altitude | 2000 m maximum | |
| Relative humidity | Operating | < 80% to 30 °C, < 70% to 40 °C, < 40% to 50 °C |
| Storage | < 95%, non-condensing. | |
| Safety | IEC 61010-1: 300 V CAT II, Pollution Degree 2 | |
| Analog low isolation | 20 V | |
| Electromagnetic environment | IEC 61326-1: Controlled | |
| Line power | 47 Hz to 63 Hz; ±10% 100 V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V | |
| Power consumption | 300 VA | |
| Dimensions | Height | 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet |
| Width | 43.2 cm (17 in), standard rack width | |
| Depth | 64.8 cm (25.5 in), overall; 59.4 cm (23.4 in), rack depth | |
| Weight | 27 kg: (62 lbs.) | |
| Absolute uncertainty definition | 5730A uncertainty specifications include stability, temperature coefficient, linearity, load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated | |
| Specification confidence interval | 99% and 95% | |
N/A
No resources available for this product.
No reviews yet. Be the first to review this product!