Fluke 732C and 734C DC Voltage Reference Standards
Precision Voltage Reference for Reliable Calibration
Fluke 732C and 734C are precision DC voltage reference solutions, and the Fluke 732C and 734C DC Voltage Reference Standards Price in Bangladesh is an important consideration for calibration laboratories and organizations requiring dependable electrical reference standards. These instruments are designed to provide highly stable reference voltage for demanding calibration and measurement applications where long term consistency and reliable performance are essential.
A stable voltage reference is fundamental to high precision electrical calibration. The Fluke 732C and 734C are engineered to provide dependable DC voltage references that can be used for maintaining and transferring measurement standards. Their stability helps calibration professionals establish a trusted reference when evaluating the performance of precision electrical measurement systems.
The Fluke 732C and 734C DC Voltage Reference Standards are suitable for professional calibration environments where measurement integrity is a critical requirement. They can support reference and transfer applications involving precision electrical instruments, helping laboratories maintain consistent calibration practices. Their use can contribute to improved confidence in measurement results and laboratory quality procedures.
Reference standards must maintain consistent performance over extended periods to support reliable calibration activities. The Fluke 732C and 734C are designed with stability as a key consideration, making them suitable for organizations that require dependable reference performance. Consistent voltage output can help technical teams maintain measurement traceability and reduce uncertainty during calibration processes.
Precision calibration laboratories require reference equipment that can operate reliably within controlled technical environments. The Fluke 732C and 734C provide a professional solution for laboratories involved in electrical measurement, calibration, standards maintenance, and technical verification. Their dedicated reference function makes them particularly useful where reliable DC voltage comparison is an essential part of the calibration workflow.
Measurement traceability depends on reliable reference standards and carefully controlled calibration procedures. The Fluke 732C and 734C can support laboratories in maintaining a consistent reference for electrical measurements. By incorporating dependable voltage reference equipment into the calibration process, organizations can strengthen their measurement management practices and improve confidence in the accuracy of calibrated instruments.
The performance of a calibration system depends heavily on the quality and stability of its reference equipment. The Fluke 732C and 734C are designed to serve as dependable voltage reference standards for professional applications. Their role within a calibration system can help technical personnel perform reference comparisons and maintain consistent electrical measurement practices.
Electrical metrology environments require precise and dependable reference equipment for maintaining measurement standards. The Fluke 732C and 734C are suitable for applications where stable DC voltage references are required for calibration and verification activities. They can be used by calibration laboratories, research facilities, standards organizations, and other technical environments focused on high quality electrical measurement.
Organizations considering the Fluke 732C and 734C DC Voltage Reference Standards Price in Bangladesh may require equipment capable of supporting advanced calibration and measurement requirements. These reference standards provide a professional option for laboratories seeking stable DC voltage references, dependable long term performance, and a structured approach to maintaining electrical measurement standards.
Reliable reference equipment is essential when accuracy and consistency are central to a calibration program. The Fluke 732C and 734C combine precision reference functionality with professional engineering suitable for demanding laboratory environments. They can help calibration specialists maintain dependable reference conditions and support consistent measurement performance across a range of electrical calibration activities.
Line voltage is accepted as shown in Table 1. AC line current at 120V ac is typically 0.13A. Table 1. Mains
| 732C Line Voltage Setting | Line Voltage Accepted | Frequency Accepted |
|---|---|---|
| 100 V | 90 V to 110 V | 50 Hz/60 Hz |
| 120 V | 108 V to 132 V | 50 Hz/60 Hz |
| 220 V | 198 V to 242 V | 50 Hz/60 Hz |
| 240 V | 216 V to 264 V | 50 Hz/60 Hz |
| Battery | Battery Operation | At full charge, the internal battery operates the Product for a minimum of 72hours at 23±5 °C, with 0 mA to 0.1 mA total current drain at the outputs. |
| Charging Time | <36 hours with self-contained automatic battery charger | |
| External DC Input | Rear-panel input for external 12 V dc to 15 V dc powers the Product indefinitely. The dc source must be rated ≥300 mA. | |
| Isolation | Resistance from any of the Product binding posts to earth (chassis) ground or to ac line power is >10 000 MΩ shunted by <1000 pF. | |
| Guard and Ground Terminals | Chassis ground connections are provided on both the front and rear panels. Access to the internal guard is provided by a front-panel binding post. | |
| Output Protection | All outputs can be shorted indefinitely without damage to the Product. The 10 V output can withstand voltages from other sources as follows:
|
|
| Environmental | |
|---|---|
| Specified Operation | Temperature Range: 15 °C to 35 °C |
| Relative Humidity: 0% to 90% to 28 °C, to 80% to 35 °C, and to 50% to 50 °C, Noncondensing | |
| Altitude: 0 m to 1830 m (0 ft to 6000 ft) | |
| Non-specified Operation | Temperature Range: 0 °C to 50 °C |
| Relative Humidity: 0% to 90% Noncondensing | |
| Altitude: 0 m to 3050 m (0ft to 10 000ft) | |
| Storage (Battery Removed) | Temperature Range: -40 °C to 50 °C |
| Relative Humidity: Noncondensing | |
| Altitude: 0m to 12 200 m (0 ft to 40 000 ft) | |
| Electromagnetic Compatibility | |
|---|---|
|
(EMC) The Product operates in Standards Laboratory environments where the radio frequency (RF) environment is highly controlled. |
|
| International |
IEC 61326-2-1; CISPR 11: Group 1, Class A Controlled Electromagnetic Environment Group 1 equipment has intentionally generated and/or use conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself. Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions which exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of 61326-1 when test leads and/or test probes are connected. |
| USA (FCC) | 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 |
| Korea (KCC) |
Class A Equipment (Industrial Broadcasting & Communication Equipment) This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
| Safety | |
|---|---|
| Safety | IEC 61010-1, Installation Category II, Pollution degree 2 |
| Ingress Protection | IEC 60529: IP20 |
| Mechanical Specifications | ||
|---|---|---|
| 734C Dimensions | 732C and 732C-7001 Dimensions | |
| Height | 17.8 cm (7.0 in) | 13.4 cm (5.28 in) |
| Width | 43.2 cm (17.0 in) | 9.8 cm (3.85 in) |
| Depth | 50.3 cm (19.8 in) including handles | 40.6 cm (16.0 in) |
| Weight | 30.4 kg (67 lb) | 5.91 kg (13 lb) |
10 V, 1 V, and 0.1 V are provided at separate binding posts referenced to the VCOM binding post.
Stability for the 732C outputs at Tcal ±1 °C and IN CAL indicator on is specified in Table 2.
| Output Voltage | Stability (± µV/V) | ||
| 30 Days | 90 Days | 1 Year | |
| 10 V | 0.3 | 0.8 | 2.0 |
| 1 V | 0.6 | 1.2 | 3.0 |
| 0.1 V | 1.2 | 2.9 | 9.8 |
| Output Voltage | Stability (± µV/V) | ||
|---|---|---|---|
| 30 Days | 90 Days | 1 Year | |
| 10 V | 0.3
td>
0.8 |
1.0 |
|
| 1 V | 0.6 | 1.2 | 2.5 |
| 0.1 V | 1.2 | 2.9 | 8.0 |
Output noise is specified for both day-to-day observations and for short-term observations, at k=1.
| Output Voltage | S1 (±µV/V) |
|---|