Fluke 8588A Reference Multimeter
Precision Reference Measurement for Demanding Metrology
Fluke 8588A is a precision reference multimeter designed for demanding electrical measurement, calibration, and metrology applications, making the Fluke 8588A Reference Multimeter Price in Bangladesh a relevant consideration for professional laboratories and engineering organizations. It provides a dependable measurement platform for applications where stability, repeatability, and measurement confidence are essential.
The Fluke 8588A is designed to support high precision electrical measurement in professional environments. Its reference-oriented design makes it suitable for laboratories and technical facilities that require dependable measurement results for calibration, verification, and research activities. Engineers can use the instrument as part of measurement systems where accuracy and long-term stability are important considerations.
Metrology applications demand measurement instruments that can provide consistent and dependable performance. The Fluke 8588A is designed to meet the needs of professional measurement environments, supporting calibration specialists and engineers during demanding electrical measurement tasks. Its precision-focused architecture makes it suitable for reference measurement and technical verification workflows.
Calibration laboratories can use the Fluke 8588A as part of professional measurement and verification systems. It can support calibration procedures, reference measurements, instrument comparison, and quality control activities. The instrument is particularly suitable for controlled environments where measurement consistency and dependable operation are essential for maintaining reliable calibration practices.
The Fluke 8588A can support engineers during electrical measurement and verification tasks across laboratory and technical environments. Its professional measurement capabilities can help users examine electrical performance, verify test equipment, and support engineering analysis. Reliable measurement data can contribute to better technical decision making and more consistent testing procedures.
Research and development facilities often require precision measurement equipment for evaluating electronic circuits, instruments, prototypes, and measurement systems. The Fluke 8588A provides a professional platform for advanced electrical measurement and can be integrated into research workflows where repeatable and dependable results are required.
Measurement stability is particularly important when an instrument is used as part of a reference or calibration system. The Fluke 8588A is designed for professional environments where users need dependable measurement performance throughout technical operations. Its precision-oriented design supports consistent testing and helps laboratories maintain confidence in their measurement processes.
Professional engineering teams can use the Fluke 8588A to support quality control, equipment verification, and technical testing. Reliable reference measurements can help identify measurement deviations and support consistent evaluation of electrical equipment. This makes the instrument suitable for organizations that require a structured and dependable approach to measurement quality.
The Fluke 8588A is intended for demanding laboratory and metrology environments where professional equipment reliability is essential. Its purpose-built design supports integration into technical workspaces and measurement systems. This makes it suitable for calibration laboratories, research organizations, engineering departments, and other facilities that depend on precision electrical measurement.
The Fluke 8588A can be a suitable reference measurement solution for calibration laboratories, industrial organizations, research facilities, universities, and engineering companies in Bangladesh. Professionals searching for the Fluke 8588A Reference Multimeter Price in Bangladesh can consider its applications in precision measurement, metrology, calibration support, research, quality assurance, and electrical testing.
The Fluke 8588A combines precision measurement capability with a professional reference-oriented design for demanding technical environments. It can support calibration specialists, engineers, researchers, and laboratory technicians in performing dependable electrical measurements. For organizations seeking a professional reference multimeter for advanced measurement and metrology applications, the Fluke 8588A provides a reliable platform for precision testing and verification.
| Key feature and specification comparison | 8588A | 8558A |
| DC voltage | 100 mV – 1000 V | 100 mV – 1000 V |
| AC voltage | 10 mV – 1000 V, 1 Hz – 10 MHz | 10 mV – 1000 V, 1 Hz – 10 MHz |
| Resistance, LoI, HV | 1 Ω - 10 GΩ | 1 Ω - 10 GΩ |
| DC current | 10 uA – 30 A | 10 uA – 2 A |
| AC current | 10 uA – 30 A, 1 Hz to 100 kHz | 10 uA – 2A, 1 Hz to 100 kHz |
| Digitize V | 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW | 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW |
| Digitize I | 10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW | 10 uA - 2 A, 5 MSamples/s, up to 4 MHz BW |
| Frequency (V, I, BNC) | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz |
| Temperature | PRT / Thermocouple (ext CJC) | PRT / Thermocouple (ext CJC) |
| Capacitance | 1 nF – 100 mF | No |
| RF power | R&S NRP Series | No |
| Ext. dc current and ac current | A40B current shunt and other shunts | No |
| Graphical display | Yes | Yes |
| Visual Connection Management ® | Yes | Yes |
| Programmable front/rear input switching | Yes | Yes |
| Ratio difference, deviation - ohms, voltage, current | Yes | Yes |
| External 10 MHz ref clock, 50 Ω/Hi-Z | Yes | Yes |
| A40B and other shunt asset management | Yes | No |
| GPIB 488.2, Ethernet, USB TMC | Yes | Yes |
| SCPI command compatibility | Yes | Yes |
| 3458A emulation, 8508A emulation | Yes | Yes |
| Volatile memory | 15 million | 15 million |
| Level and other trigger | Yes | Yes |
| FFT onboard | Yes | No |
| Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits | Yes | Yes |
| Function | 8588A uX/X of reading + uX/X of range | 8558A uX/X of reading + uX/X of range | ||||
| 95% | 99% | 95% | 99% | |||
| DC voltage | 10 V | relative | 2.7 + 0.05 | 3.5 + 0.06 | 4.0 + 0.06 | 5.2 + 0.08 |
| absolute | 2.8 + 0.05 | 3.6 + 0.06 | 4.1 + 0.06 | 5.3 + 0.08 | ||
| AC voltage | 10 V, 1 kHz | relative | 60 + 5 | 77 + 6.5 | 80 + 10 | 103 + 13 |
| absolute | 64 + 5 | 83 + 6.5 | 90 + 10 | 116 + 13 | ||
| Resistance | 10 kΩ | relative | 7 + 0.5 | 9 + 0.6 | 10 + 0.6 | 13 + 0.7 |
| absolute | 7.2 + 0.5 | 9.2 + 0.6 | 10.3 + 0.6 | 13.3 + 0.7 | ||
| DC current | 1 mA | relative | 6.5 + 4 | 8.4 + 5 | 9 + 5 | 12 + 6 |
| absolute | 7.6 + 4 | 10 + 5 | 9.8 + 5 | 13 + 6 | ||
| AC current | 1 mA, 1 kHz | relative | 250 + 50 | 323 + 65 | 300 + 100 | 387 + 129 |
| absolute | 260 + 50 | 335 + 65 | 310 + 100 | 400 + 129 | ||
| Frequency | BNC,1 kHz | relative | 0.5 uHz/Hz | 0.5 uHz/Hz | 0.5 uHz/Hz | 0.5 uHz/Hz |
| Temperature | PRT 100 Ω | relative | ± 5 mK | ± 5 mK | ± 5 mK | ± 5 mK |
| Capacitance | 1 uF | relative | 400 + 100 | 516 + 129 | N/A | N/A |
| absolute | 406 + 100 | 523 + 129 | N/A | N/A | ||
95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2).
Bench Multimeter Selection Guide
| Model | Resolution | Accuracy | Application |
| 8588A | 8.5 | 2.7 µV/V 95% confidence level, 1 year relative accuracy | Metrology |
| 8558A | 8.5 | 4.0 µV/V 95% confidence level, 1 year relative accuracy | High-Speed Automation |
| 8845A/8846A | 6.5 | Basic V dc accuracy of up to 0.0024 % | Bench |
| 8808A | 5.5 | Basic V dc accuracy of 0.015 % | Bench |
Rack mounts and hardware (2)
Other (2)
Test leads, probes and clips (1)
Cases and holsters (1)
No resources available for this product.
No reviews yet. Be the first to review this product!