Fluke 96040A Low Phase Noise Reference Source

Precision Reference Signals for Advanced Frequency Calibration

  • Home
  • Products
  • Fluke 96040A Low Phase Noise Reference Source
Fluke 96040A Low Phase Noise Reference Source
Brand: Fluke
Category: RF Calibrators
Availability: Ready Stock
Always authentic product We only sell 100% authentic products
Fast Shipping Receive products in amazing time.
Easy returns Return policy that let you shop at ease
Secure shopping Your data is always protected

Fluke 96040A Low Phase Noise Reference Source Price in Bangladesh

Fluke 96040A Low Phase Noise Reference Source is a precision signal source, and the Fluke 96040A Low Phase Noise Reference Source Price in Bangladesh is relevant for laboratories and engineers requiring exceptionally stable and clean reference signals for advanced frequency measurement applications. Designed for demanding calibration and measurement environments, this reference source supports high quality frequency reference generation with very low phase noise characteristics. It is particularly useful when signal purity and frequency stability are important factors in the evaluation, calibration, and verification of precision frequency measurement equipment.

Low Phase Noise Reference Performance

Low phase noise is essential in applications where even small variations in the reference signal can influence measurement accuracy. The Fluke 96040A is designed to provide a clean and stable reference signal that helps reduce the impact of unwanted phase fluctuations during precision measurements. This makes it suitable for calibration laboratories, frequency standards applications, communications testing, and other technical environments where signal integrity is a critical consideration. Its low noise characteristics support reliable comparison and evaluation of precision frequency equipment.

Precision Frequency Reference

A dependable frequency reference is fundamental to many advanced measurement systems. The Fluke 96040A provides a stable reference source that can support precision frequency measurement and calibration activities. Engineers can use the instrument as a reference when evaluating frequency counters, measurement systems, and other precision electronic equipment. Its application-focused design makes it useful for laboratories that require repeatable and dependable reference signals during calibration and verification procedures.

Calibration Laboratory Applications

The Fluke 96040A Low Phase Noise Reference Source is well suited to professional calibration laboratories where measurement uncertainty and signal quality are important considerations. It can support calibration and verification activities involving precision frequency measurement equipment. By providing a stable reference signal, the instrument helps laboratories establish consistent test conditions and perform reliable comparisons. This makes it a valuable addition to environments focused on metrology, frequency calibration, electronic measurement, and high precision testing.

Frequency Measurement and Verification

Engineers working with precision frequency measurement systems need reference signals with dependable stability and low noise. The Fluke 96040A can be used to verify the performance of frequency measurement equipment by providing a controlled reference source. This can support technical evaluation, instrument verification, system testing, and calibration workflows. Its low phase noise performance helps maintain signal quality during measurements where frequency stability and signal purity have a direct influence on the quality of the results.

Suitable for Advanced Metrology

Metrology applications demand measurement equipment that can provide consistent and traceable performance. The Fluke 96040A is designed for professional environments where frequency references play an important role in precision measurement. Its low phase noise characteristics make it suitable for advanced frequency metrology, calibration laboratories, research facilities, and specialized electronic measurement applications. Engineers can integrate the reference source into measurement systems where signal stability is necessary for accurate evaluation and verification.

Reliable Engineering Solution

Professional reference equipment must provide stable performance during repeated measurement and calibration activities. The Fluke 96040A is engineered for demanding technical environments where signal quality and reliability are essential. Its professional design supports use in laboratories and specialized measurement facilities. When incorporated into a properly configured calibration system, the reference source can help engineers maintain consistent measurement conditions and improve the reliability of frequency comparison and verification procedures.

Applications in Research and Development

Research and development teams working with precision timing, frequency generation, communications equipment, and electronic measurement systems can benefit from a high quality reference source. The Fluke 96040A can support experimental measurements, equipment characterization, design verification, and development activities where low phase noise is important. Its clean reference signal can provide a dependable basis for evaluating frequency related performance and investigating the behavior of precision electronic systems.

Fluke 96040A for Bangladesh Calibration and Testing

The Fluke 96040A Low Phase Noise Reference Source can be a valuable solution for calibration laboratories, research institutions, telecommunications testing facilities, electronics manufacturers, universities, and professional engineering organizations in Bangladesh. Its precision reference capabilities support applications where frequency stability and low phase noise are important. Engineers can use it as part of advanced calibration and measurement systems for evaluating precision frequency instruments and maintaining reliable testing conditions.

Precision Reference Source for Professional Measurement

The Fluke 96040A combines low phase noise performance, stable frequency reference capability, and professional engineering design for advanced measurement applications. It is suitable for engineers and metrology professionals who require a dependable reference source for calibration, verification, research, and precision frequency measurement. By providing a clean and stable reference signal, the instrument can support accurate technical evaluation and help maintain consistent performance across demanding frequency measurement applications.

 

Key Features: Fluke 96040A Low Phase Noise Reference Source

  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • “What you set is what you get” accurate signal delivery direct to the DUT input
  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods

Specifications: Fluke 96040A Low Phase Noise Reference Source

96040A summary specifications*
  Frequency specifications Level specifications
(50 Ω output, see extended specifications for 75 Ω)
Range 1 mHz to 4 GHz -130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)
Resolution 10 µHz 0.001 dB
Accuracy ± 0.05 ppm ± 5 µHz Down to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm
Attenuation   ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz
VSWR ≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)
Harmonics and spurious –60 dBc harmonics, –78 dBc spurious to 1 GHz
Phase noise at 1 GHz –144 dBc/Hz, typical, at 10 kHz to 100 kHz offset
Modulation AM, FM, PM, internal and external. Frequency pull and external leveling
Frequency sweep 1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span
Frequency counter Internal 50 MHz frequency counter
Temperature Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.
Standard interfaces IEEE-488.2 (GPIB)
GPIB command emulation 9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.
Dimensions (HxWxD) 146 mm x 442 mm x  551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit
Weight 18 kg (40 lb)
*Key specifications summary. Refer to the extended specifications for full and detailed specifications.

Includes: Fluke 96040A Low Phase Noise Reference Source

Model Name Description
96040A

4 GHz RF Reference Source including 50 Ω Leveling Head

96040A/75

4 GHz RF Reference Source including 50 Ω and 75 Ω Leveling Heads

No resources available for this product.

No reviews yet. Be the first to review this product!

Write a Review