Fluke 96270A 27 GHz Low Phase Noise Reference Source
Ultra Stable Reference Performance for Precision Frequency Measurement
Fluke 96270A 27 GHz Low Phase Noise Reference Source is a high frequency precision signal source, and the Fluke 96270A 27 GHz Low Phase Noise Reference Source Price in Bangladesh is relevant for calibration laboratories and engineers working with advanced frequency measurement systems. Designed for demanding metrology and electronic measurement applications, this reference source provides high quality reference signals with low phase noise characteristics. It is suitable for professional environments where signal purity, frequency stability, and dependable measurement performance are essential for calibration, verification, and technical analysis.
Low phase noise is an important characteristic when working with precision frequency measurement and calibration systems. The Fluke 96270A is designed to provide clean and stable reference signals that help minimize unwanted phase fluctuations during measurement. This makes the instrument suitable for applications where signal quality directly influences measurement performance. Engineers can use the reference source to establish controlled signal conditions when evaluating precision frequency instruments, electronic measurement systems, and other high frequency equipment.
The Fluke 96270A provides a high frequency reference solution for advanced measurement applications. Its high frequency capability allows engineers to work with sophisticated electronic and RF measurement systems that require a reliable reference signal. The instrument can support frequency calibration, verification, characterization, and system testing in professional laboratories. Its application-focused design makes it suitable for organizations involved in precision electronics, telecommunications, RF testing, and advanced metrology.
Accurate frequency calibration requires a stable and dependable reference source. The Fluke 96270A can be integrated into calibration workflows where frequency measurement equipment needs to be evaluated against a high quality reference. Engineers can use the source to support calibration and verification activities involving frequency counters, signal measurement systems, and other precision instruments. Its low phase noise performance contributes to maintaining signal integrity during demanding calibration procedures.
Metrology laboratories require reliable reference equipment to maintain consistent and repeatable measurement conditions. The Fluke 96270A Low Phase Noise Reference Source is designed for advanced frequency metrology applications where signal stability and purity are critical. It can support precision measurement, instrument verification, research, and frequency standard related applications. By providing a controlled reference signal, the instrument helps engineers perform detailed evaluations of frequency measurement equipment and related systems.
The Fluke 96270A can be useful in RF and electronic testing environments where high frequency reference signals are required. Engineers can use the instrument for equipment characterization, performance verification, design validation, and laboratory testing. A clean reference signal can help establish reliable test conditions and support accurate comparison between measurement systems. This makes the reference source suitable for specialized laboratories and engineering teams working with advanced electronic and communication technologies.
Research and development projects involving high frequency electronics often require precision reference signals for experimental measurements and system evaluation. The Fluke 96270A can support development activities involving frequency generation, RF systems, electronic instrumentation, and precision timing applications. Engineers can use the source to establish stable reference conditions while investigating equipment performance and validating design characteristics. Its professional measurement capabilities make it suitable for demanding laboratory environments.
Precision reference equipment must deliver dependable performance during repeated measurement and calibration tasks. The Fluke 96270A is designed for professional environments where measurement stability and signal quality are important. Its engineering-focused design supports use in calibration laboratories, research facilities, electronic testing environments, and specialized industrial applications. When properly integrated into a measurement system, it can provide a reliable reference for advanced frequency evaluation and verification.
The Fluke 96270A 27 GHz Low Phase Noise Reference Source can be a valuable solution for calibration laboratories, telecommunications organizations, electronics manufacturers, research institutions, universities, and specialized engineering companies in Bangladesh. Its high frequency reference capability and low phase noise performance make it suitable for advanced measurement applications. Engineers can use it as part of professional calibration and verification systems where frequency accuracy, signal stability, and repeatable test conditions are important.
The Fluke 96270A combines high frequency reference generation, low phase noise performance, and professional engineering capability in a specialized measurement solution. It is designed for engineers and metrology professionals who require a dependable reference source for precision calibration, RF testing, research, and frequency measurement. By providing a clean and stable reference signal, the instrument can support reliable technical evaluation and help maintain consistent measurement performance in demanding laboratory and engineering applications.
| 96270A summary specifications* | ||
| Frequency specifications | Level specifications | |
| Frequency/ Level Range | Leveling Head O/P [50 Ω]: 1 mHz to 4 GHz Microwave O/P Direct: 1 mHz to 27 GHz [with LL option] Microwave O/P with HF option: 1 kHz to 27 GHz [with LL option] |
-130 to +24 dBm to 125 MHz, +14 dBm at 4 GHz -4 [-100] to +24 dBm, >1.4 GHz: +20 dBm, [>20 GHz: +18 dBm] -10 [-35] to +18 dBm, >1.4 GHz: +14 dBm, [>20 GHz: +12 dBm] |
| Resolution | 10 µHz | 0.001 dB |
| Frequency accuracy | ± 0.05 ppm ± 5 µHz | |
| Level accuracy (into 50 Ω): | Leveling Head O/P: Down to -48 dBm; ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz 10 MHz to 128 MHz; ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm Microwave O/P Direct: Typically ± 0.5 dB to 4 GHz, ± 0.5 dB to 26.5GHz Microwave O/P with HF option (after self-characterization): Power flatness uncertainty; ± 0.05 dB at 100 MHz, ± 0.07 dB at 1 GHz, ± 0.1 dB at 12 GHz, ± 0.16 dB at 26.5 GHz % Power (Cal Factor) uncertainty with factory calibration; ± 1.06 % at 100 MHz, ± 1.42 % at 1 GHz, ± 3.52 % at 26.5 GHz % Power (Cal Factor) uncertainty with reference sensor calibrated with typical state-of-the-art uncertainty and vector corrections for mismatches at splitter output port; ± 0.37 % at 100 MHz, ± 0.49 % at 1 GHz, ± 2.18 % at 26.5 GHz |
|
| Attenuation accuracy (into 50 Ω) | Leveling Head O/P: ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB Relative to +10 dBm, 10 Hz to 128 MHz | |
| VSWR | Leveling Head O/P (50 Ω): ≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 x f (GHz) Microwave O/P: direct ≤ 2.0 (typical), HF option splitter device ≤ 1.22 | |
| Harmonics and sub-harmonics | Harmonics ≤1 GHz: -60 dBc, >1 GHz: -55 dBc; sub-harmonics ≤ 4 GHz: none, >4GHz: -60 dBc | |
| Spurious ≥ 3 kHz offset | ≤ -84 dBc at 500 MHz, ≤ -78 dBc at 1 GHz, ≤ -66 dBc at 4 GHz, ≤ -48 dBc at 27 GHz | |
| Phase noise at 1 GHz | –144 dBc/Hz, typical, at 10 kHz to 100 kHz offset | |
| Modulation | AM, FM, PM, internal and external to 4 GHz (Leveling Head and Microwave O/P); frequency pull and external leveling | |
| Frequency sweep | 1 mHz to 4 GHz (Leveling Head); 1 mHz to 27 GHz (Microwave O/P). Linear or logarithmic. Stop-start or center-span | |
| Frequency counter | Internal 300 MHz frequency counter | |
| Power meter readout compatibility | Rhode & Schwarz NRP-Z series thermal sensor models 51, 52, 55.03, 55.04, 56, 57 and 58 | |
| Temperature | Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance Storage: -20 °C to +70 °C | |
| Standard interfaces | IEEE-488.2 (GPIB) | |
| GPIB command emulation | 9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A, HP8340A, HP8360 B-Series; Agilent E8257 Series | |
| Dimensions (HxWxD) | 146 mm x 442 mm x 551 mm (5.8 in x 17.4 in x 21.7 in) including handles. Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit | |
| Weight | 18 kg (40 lb) | |
| *Key specifications summary. Refer to the 96270A Extended Specifications for detailed specifications, including the 75 ohm output Leveling Head. | ||