Hioki FT3151 Analog Earth Tester

Dependable Analog Testing for Professional Grounding Applications

Hioki FT3151 Analog Earth Tester
Brand: Hioki
Category: Earth Ground Resistance Tester
Availability: Ready Stock
Always authentic product We only sell 100% authentic products
Fast Shipping Receive products in amazing time.
Easy returns Return policy that let you shop at ease
Secure shopping Your data is always protected

Hioki FT3151 Analog Earth Tester Price in Bangladesh

Hioki FT3151 is a professional analog earth resistance testing instrument, and the Hioki FT3151 Analog Earth Tester Price in Bangladesh is a relevant search term for electrical engineers, contractors, technicians, and maintenance professionals looking for a dependable grounding measurement solution. Designed for practical electrical inspection, this earth tester provides a straightforward approach to checking grounding systems and evaluating earth resistance. Its analog measurement design, durable construction, and field oriented operation make it suitable for electrical installation, maintenance, commissioning, and grounding system inspection.

Reliable Earth Resistance Testing

The Hioki FT3151 is designed to support reliable measurement of earth resistance in electrical grounding systems. Proper earth resistance testing is important for evaluating the effectiveness of an earthing installation and identifying conditions that may require corrective maintenance. The instrument provides professionals with a dedicated solution for grounding inspections, helping them assess electrical installations systematically and maintain appropriate grounding performance.

Practical Analog Measurement

Analog testing instruments remain useful in many professional electrical applications because they provide a direct and intuitive indication of measurement behavior. The FT3151 uses an analog display system that allows technicians to observe the measurement response while carrying out a grounding test. This can be particularly useful when working in field environments where a simple, clearly visible indication is preferred. Its conventional operating concept also makes it practical for technicians familiar with analog electrical testing equipment.

Suitable for Grounding System Inspection

Grounding systems require regular inspection to maintain dependable electrical performance. Environmental changes, soil conditions, corrosion, damaged conductors, and deteriorated connections can influence grounding characteristics over time. The Hioki FT3151 can be used as part of routine inspection and maintenance procedures to evaluate earth resistance and help identify potential grounding issues. Its dedicated earth testing function makes it a practical instrument for electrical service professionals.

Field Oriented Design

Earth resistance measurements are frequently performed at construction sites, industrial facilities, commercial properties, utility installations, and other locations where portability and durability are important. The Hioki FT3151 is designed for practical field operation, allowing technicians to transport the instrument between testing locations. Its professional construction supports regular use during electrical inspection and maintenance activities while providing a straightforward testing experience.

Easy Operation for Technicians

Efficient electrical testing depends on an instrument that can be operated confidently in real working conditions. The FT3151 follows a practical operating concept that helps trained technicians perform earth resistance measurements without unnecessary complexity. The analog indication provides an immediate visual reference during testing, while the dedicated controls support a focused grounding measurement workflow. This makes the instrument suitable for technicians who value simple and direct test operation.

Applications in Electrical Installation

The Hioki FT3151 can be used during electrical installation and commissioning activities to verify grounding conditions. Contractors and commissioning engineers can use earth resistance measurements as part of their inspection procedures when establishing or evaluating grounding systems. Testing can also support troubleshooting when an electrical installation shows symptoms that may be associated with grounding problems. Its dedicated functionality makes it useful for a variety of electrical installation environments.

Industrial and Commercial Maintenance

Industrial plants and commercial facilities depend on effective grounding systems to support electrical safety and reliable equipment operation. Maintenance teams can use an earth tester during scheduled inspections to monitor grounding conditions and investigate changes in system performance. The Hioki FT3151 provides a practical measurement solution for maintenance professionals who need a dedicated instrument for grounding system assessment.

Durable Construction for Professional Use

Professional test instruments are often exposed to frequent transportation, handling, and demanding working environments. The Hioki FT3151 is designed with durability and practical field use in mind. Its robust construction makes it suitable for technicians who regularly perform electrical testing outside controlled laboratory conditions. A durable instrument can help organizations maintain consistent testing practices across construction, service, and maintenance projects.

Why Choose Hioki FT3151

The Hioki FT3151 is a practical choice for professionals who require a dedicated analog earth tester for grounding inspection. Its direct analog measurement approach, professional construction, and field oriented design make it suitable for routine earth resistance testing. Electrical contractors, engineers, technicians, facility managers, and maintenance teams can use the instrument for grounding assessment during installation, commissioning, preventive maintenance, and troubleshooting.

Professional Grounding Measurement Solution

For professionals searching for a dependable analog earth tester, the Hioki FT3151 offers a straightforward solution for evaluating grounding systems. Its practical design and dedicated earth resistance testing capability make it suitable for a wide range of electrical applications. With proper testing procedures and qualified operation, the instrument can support effective grounding inspection and help electrical professionals maintain reliable and properly evaluated earthing systems.

Key Features: Hioki FT3151 Analog Earth Tester

  • The three-electrode method, Two-electrode method (Simple Measurement)
  • Wide measurement range for 0 to 1150 Ω, based on EN standard
  • Switchable measurement frequency to reduce the effects of power supply harmonics
  • Dramatically faster setup: Comes with improved grounding rods and cord winders.

Specifications: Hioki FT3151 Analog Earth Tester

Measurement system AC potentiometer method, Three-electrode method/ two-electrode method (switchable)
Measuring frequency: 575 Hz/ 600 Hz
Measurement current: Three-electrode method: 15 mA rms or less; Two-electrode method: 3 mA rms or less
Open circuit voltage: 50 V AC rms or less
Measurement range 10 Ω (0 to 11.5 Ω) 100 Ω (0 to 115 Ω) 1000 Ω (0 to 1150 Ω)
Nominal Deviation ±0.25 Ω ±2.5 Ω ±25 Ω
Functions Auxiliary earth resistance check S (P)/ H(C)
Earth potential measurement 0 to 30 V, Nominal Deviation: ±3.0 % f.s.
Power supply LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle)
Dimensions and mass 164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D, 760 g (26.8 oz)

Includes: Hioki FT3151 Analog Earth Tester

  • Hioki FT3151 ANALOG EARTH TESTER

No resources available for this product.

No reviews yet. Be the first to review this product!

Write a Review