UNI-T UT575B Double Clamp Multifunctional Earth Tester

Advanced Ground Testing with Double Clamp Convenience

  • Home
  • Products
  • UNI-T UT575B Double Clamp Multifunctional Earth Tester
UNI-T UT575B Double Clamp Multifunctional Earth Tester
Brand: Uni-T
Category: Earth Ground Resistance Tester
Availability: Ready Stock
Always authentic product We only sell 100% authentic products
Fast Shipping Receive products in amazing time.
Easy returns Return policy that let you shop at ease
Secure shopping Your data is always protected

UNI-T UT575B Double Clamp Multifunctional Earth Tester Price in Bangladesh

UNI-T UT575B is a versatile grounding measurement instrument, and the UNI-T UT575B Double Clamp Multifunctional Earth Tester Price in Bangladesh is a relevant search term for electrical engineers, contractors, maintenance technicians, and testing professionals seeking an advanced solution for earth resistance and grounding system inspection. Designed for professional field applications, this multifunctional earth tester combines several grounding measurement methods with a practical double clamp configuration. Its flexible testing capabilities make it suitable for inspecting complex grounding systems where conventional testing methods may be difficult or time consuming.

Multifunctional Ground Testing

The UNI-T UT575B is designed to support comprehensive grounding system evaluation across a variety of electrical installations. Its multifunctional approach allows technicians to perform different types of earth and grounding measurements using a single professional instrument. This reduces the need to carry multiple dedicated testers and helps streamline inspection procedures. The instrument is suitable for electrical maintenance, commissioning, troubleshooting, and periodic grounding system assessment.

Double Clamp Measurement Technology

One of the key advantages of the UT575B is its double clamp testing capability. This measurement approach can be particularly useful when working with interconnected grounding systems where disconnecting the grounding conductor is inconvenient. The double clamp method allows technicians to perform measurements efficiently while maintaining the existing grounding arrangement. This provides greater convenience during maintenance and inspection of operational electrical systems.

Efficient Ground Resistance Inspection

Accurate assessment of grounding resistance is essential for evaluating the performance of an earthing system. The UT575B provides professionals with a dedicated instrument for investigating grounding conditions and identifying potential issues. By supporting practical measurement techniques, the tester can help engineers evaluate grounding systems during installation, commissioning, preventive maintenance, and troubleshooting. Consistent earth testing also supports better documentation and monitoring of grounding system performance.

Practical Solution for Complex Grounding Systems

Large industrial and commercial installations may contain interconnected grounding electrodes, equipment grounding conductors, and multiple earth paths. Conventional testing techniques can sometimes require additional preparation or temporary disconnection of parts of the grounding system. The double clamp functionality of the UT575B provides a convenient alternative for suitable applications, helping technicians perform measurements more efficiently in complex grounding environments.

User Friendly Operation

A professional electrical tester should combine advanced functionality with straightforward operation. The UNI-T UT575B is designed to provide a practical user interface that helps technicians select appropriate measurement functions and review test results during fieldwork. Its multifunctional design allows users to perform several grounding related assessments from one instrument, helping simplify the testing workflow and improve productivity during service and inspection activities.

Suitable for Electrical Maintenance

Grounding performance can change due to corrosion, environmental conditions, loose connections, soil characteristics, equipment modifications, and other factors. Regular inspection helps maintenance teams identify changes before they develop into more significant electrical concerns. The UT575B can be used as part of preventive maintenance programs to evaluate grounding systems and support troubleshooting activities. Its flexible measurement capabilities make it useful for technicians responsible for maintaining electrical safety and system reliability.

Industrial Applications

The UNI-T UT575B is suitable for a wide range of industrial grounding applications. It can be used in manufacturing facilities, power distribution installations, substations, commercial buildings, telecommunications infrastructure, construction projects, and other electrical environments. Engineers and technicians can use the tester to investigate grounding performance during installation and commissioning or as part of routine maintenance programs. Its double clamp capability is particularly valuable when testing interconnected grounding arrangements.

Construction and Commissioning

During the installation of a new electrical system, verifying the grounding arrangement is an important part of commissioning. The UT575B can support contractors and commissioning engineers in evaluating earth resistance and other grounding characteristics. Its portable design and versatile measurement functions make it suitable for moving between different testing locations during a project. This can help testing teams perform grounding inspections efficiently while maintaining a systematic commissioning workflow.

Durable Field Performance

Electrical testing instruments used in industrial and construction environments must be capable of handling regular transportation and demanding field conditions. The UT575B is designed for professional use, combining practical portability with a construction intended for repeated electrical testing. Its field oriented design makes it suitable for technicians who regularly perform grounding measurements across different sites and installation environments.

Why Choose UNI-T UT575B

The UNI-T UT575B is a strong choice for professionals who need more than a basic earth resistance tester. Its multifunctional measurement capability and double clamp technology provide additional flexibility for inspecting grounding systems, particularly where conventional testing arrangements are inconvenient. Electrical engineers, maintenance professionals, contractors, and testing specialists can benefit from having a versatile instrument capable of supporting different grounding inspection requirements.

Professional Grounding Test Solution

For users searching for an advanced multifunctional earth tester, the UNI-T UT575B provides a practical solution for professional grounding system assessment. Its double clamp measurement capability, flexible testing approach, user friendly operation, and field oriented construction make it suitable for demanding electrical inspection applications. With appropriate testing procedures and qualified operation, the instrument can help professionals evaluate grounding performance and support safer, more reliable electrical systems.

Key Features: UNI-T UT575B Double Clamp Multifunctional Earth Tester

  • Multiple measurement methods
  •  2/3/4 wires: 0.00Ω~300.00KΩ;
  •  Selective method:0.00Ω~3000Ω;
  • Double clamp method: 0.01Ω~100Ω;
  • Ground voltage: AC 0.0V~100.0V (auto range)
  • Ground current: AC 0.00mA~600.0A (auto range)
  •  Soil resistivity: 0.00Ωm~9000KΩm (0.01Ωm)
  •  Strong anti-interference: 128Hz/111Hz/105Hz/94Hz(auto range)
  •  Large clamp jaw diameter: up to 70mm
  • Data storage: 2000 set
  • PC software analysis via USB B
  • 9. Audible alarm function

Specifications: UNI-T UT575B Double Clamp Multifunctional Earth Tester

Models UT575B
Earth resistance (2/3/4 wire testing) 300.00kΩ
Earth resistance (selective method) 3000Ω
Earth resistance (double clamp method) 100Ω
Soil resistivity 9000kΩ
AC earth voltage 100.0V
AC earth current 600.0A
Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC Auto)
Short circuit test current AC   250mA max
Open circuit test voltage AC   40V max
Manual range auto range(V & A)
Auto power off ●
Low battery indication ●
Data hold ●
Data storage 2000
LCD backlight ●
Alarm function ●
Full icon display ●
Poor contact display –
Over-range display ●
 2-wire testing ●
 3-wire testing ●
 4-wire testing ●
Disturbance voltage –
Disturbance frequency –
Earth resistance RH and RS test –
Compensating resistance RK test –
Certificates ROW

N/A

No resources available for this product.

No reviews yet. Be the first to review this product!

Write a Review